ADJUSTMENTS AND SETTINGS
Rail Lifted
Sensors
1. Select Maintenance.
2. Select Diagnostics.
3. Use Next or Previous to highlight Rising Table.
4. Select Select Module.
5. Ensure that Home Rising Table is highlighted.
6. Select Run Diagnost.
7. Select Exit.
8. Use Next or Previous to highlight Rail System.
9. Select Select Module.
10. Ensure that Home Rail Width is highlighted.
11. Select Run Diagnost.
12. Remove the left and right hand safety covers to gain access to the rear rail.
13. Place a 0.5mm feeler gauge between the rail shock absorber on the rear
right rail transport leg and the rail stop bar (clatter bar).
Right Transport Leg
Rear Rail
Front View of Rail System
Left Transport Leg
Linear Bearing
Feeler Gauge
Rail Stop Bar
(Clatter Bar)
Opto Vane
Bracket
Opto Vane
Opto
Shock Absorber
Sensor LED
Enlarged View of Right Rail Opto
TRANSPORT RAILS MODULE
ADJUSTMENTS AND SETTINGS
16.6 Technical Reference Manual Chapter Issue 4 Jan 10
14. Adjust the vane bracket using a 2.5mm Allen key, so that the sensor LED is
Off with a 0.5mm feeler gauge fitted and On with a 0.7mm feeler gauge
fitted.
15. Repeat Steps 13 and 14 for left hand end of the rear rail.
16. Select Adjust, the following window is displayed:
17. Use Incr. or Decr. to set the Board Width to 50mm.
18. Select Exit.
19. Use Next or Previous to highlight Drive Rail To Board Width.
20. Select Run Diagnost.
21. Repeat Steps 13 to 15 for setting the vane at the 50mm width.
22. Use Next or Previous to highlight Home Rail Width.
23. Select Run Diagnost.
24. Repeat Steps 13 to 15 at the home position.
25. Use Next or Previous to highlight Cycle Rails.
26. Select Run Diagnost.
27. Ensure the left and right sensor LED’s remain Off over the full travel of the
rail.
28. Select Stop.
29. Select Exit.
30. Select Exit.
31. Select Back.
Rail System Test Parameters
BOARD WIDTH
CYCLE COUNT
250.0
50
mm
Cycles
TRANSPORT RAILS MODULE
ADJUSTMENTS AND SETTINGS
Chapter Issue 4 Jan 10 Technical Reference Manual 16.7
Board at Left/
Right Optos
The board at left/right optos switching threshold can be adjusted by means of a
sensitivity control. This ensures that when a board is fed into the machine (via
the transport belts) the sensor output switches to ON.
To achieve an optimum setting carry out the following procedure:
1. Place a board on the rails covering the sensor.
2. Turn the sensitivity control fully anti-clockwise, ensure that the amber LED
is extinguished.
3. Re-adjust the sensitivity control clockwise until the amber LED illuminates.
NOTE
If the amber LED is flashing, this indicates a week signal. Re-adjust the
sensitivity control.
4. Remove the board from the rails and confirm the amber LED extinguishes.