YSM40 Mainte_E - 第154页

Appendix Appendix Contents 1. Specifications A- 1 1.1 Air regulator unit A- 1 1.2 Power connection terminals A- 2 1.3 Connection between machines A- 3 1.3.1 PREVIOUS INTERF ACE connector A- 3 1.3.2 NEXT INTERF ACE connec…

100%1 / 160
5-13
5
Lubrication points and schedule
3.4 Both sides of cATS
Both sides of cATS
Cam follower
Cam follower on right side
of cATS
Grease gun:
Manual lubrication:
Cam follower on left side
of cATS
Lubrication section Lubrication point Interval Procedure
Cam follower on both sides 10 Monthly Manual lubrication
53509-N5-00
Appendix
Appendix
Contents
1. Specifications A-1
1.1 Air regulator unit A-1
1.2 Power connection terminals A-2
1.3 Connection between machines A-3
1.3.1 PREVIOUS INTERFACE connector A-3
1.3.2 NEXT INTERFACE connector A-4
2. Warranty A-5
A-1
Appendix
1. Specifications
1.1 Air regulator unit
Theairregulatorforcontrollingtheairpressuretothemachine'spneumaticunitsislocatedatthelowerleft
panelontherearsideofthemachine.Specifytheappropriateairpressuresettingshownbelow.
Air pressure regulator and pressure gauge
Setting air pressure gauge
[PNEUMATIC]
Setting air pressure regulator
[PNEUMATIC]
Air supply/exhaust switch
Head air pressure gauge
[HEAD BLOW]
Head air pressure regulator
[HEAD BLOW]
Source air connector
53A01-N5-00
n
Supply air pressure
Thisisthepressureofthesourceairsuppliedtothemachine.Beforesettingtheairpressurewiththeairregulator,make
surethatthissupplyairpressureisinthefollowingoptimalrange.
YSM40:0.45MPato0.70MPa
n
Air pressure gauge (display)
Whenwithinthenormalrange,theairpressuredisplaysingreen.Whentheairpressureisbeyondtheupper/lowerlimit
values(airdowndetection),anerroroccurs,andtheairpressuredisplaysinred.
n
Air pressure setting values and upper/lower limit values
Head Setting Value Lower Limit Value Upper Limit Value
Setting air pressure Common 0.40Mpa (±0.01) 0.39Mpa 0.41Mpa
Head air pressure Common 0.040Mpa (±0.001) 0.039Mpa 0.041Mpa
n
Air supply/shutoff switch (valve)
Turningthisswitchtotherightshutsoffairsupplyandexhaustsairthatremainsinsidethemachine.
n
Source air connector
Prepareanairhosewithaninnerdiameterofatleast8mmhavinga40SHsocket(NittoKoki,orequivalent),andconnect
ittothisconnector.Usedry,cleanairpassedthroughanairfilter.