00197197-02-IM SetupCenter 5.1 - 第47页

Installation Setup Center Software Installation Installation Manual SIPLACE Setup Center 5.1 47 4.2.5.4 Firmware download for docking station ► Setup Center can update the fi rmwa r e of your docking station. To learn ho…

100%1 / 102
Installation
Hardware Installation Optional: Docking Station
46 Installation Manual SIPLACE Setup Center 5.1
Compressed Air and Power Supplies
Connect to the compressed air supply.
Set the pressure reducer on the pneumatic connection (external) to 5.5 bar.
Switch off the power supply and connect the CAN Bus cable to the device.
Switch on the power supply.
You will find a control lamp on the front of the device. This will shine when power is correctly supplied
to the device.
NOTICE
The compressed air and power connections can be found on the back of the docking station.
DANGER
Never cover the air discharge opening in the integrated fan and the ventilation slits on the side
of the device!
Covering these could lead to overheating and destruction of the power pack.
DANGER
Make sure that nobody is using the connected change over table when you switch the power
on.
Docking station: compressed air and power supplies
Docking Station X
1. Compressed Air Connection
2. Power Connection
3. Set Compressed Air
Installation
Setup Center Software Installation
Installation Manual SIPLACE Setup Center 5.1 47
4.2.5.4 Firmware download for docking station
Setup Center can update the firmware of your docking station.
To learn how to update the firmware of your docking station, please refer to the chapter "Docking
Station Firmware Download" in the Online Help Setup Center.
4.3 Software Installation
4.3.1 Setup Center
The following steps have to be performed to install the required system components on the specific com
-
puter:
1. General settings, steps that are identical for all setup types
2. Setup types, the following setup types can be selected:
–Custom
SIPLACE Setup Center Complete
SIPLACE Setup Center GUI
SIPLACE Setup Center Server
4.3.1.1 General Settings
These steps are identical for all setup types. The subsequent steps only differ once you have selected
the setup type you require.
Run through the following steps to start the installation and then refer to the relevant section for your
specific setup type.
Step 1
Insert the SIPLACE Setup Center installation CD into the CD-ROM drive. The installation routine
starts automatically.
You can also start the installation by running the Autorun.cmd program located in the root directory
on the installation CD.
Docking Station SX
1. Set Compressed Air
2. Compressed Air Connection
3. Power Connection
NOTICE
You require administrator rights for the installation procedure!
Installation
Software Installation Setup Center
48 Installation Manual SIPLACE Setup Center 5.1
This starts the user-controlled installation of SIPLACE Setup Center; you are prompted to select the
installation language.
"Choose setup language" dialog box
Select the language you want.
Click OK.
Step 2
The Installation Wizard will guide you through the program setup process.
InstallShield Wizard box for SIPLACE Setup Center
Click Next.
NOTICE
This decision only relates to the language used during the installation routine!