1.4 Maintenance Method (2) When the [Start Oil Supply] button is pressed in the "Oil Supply" tab sheet, the following sheet appears. Fig. 4A85-2 (3) Press the [ALL] button (entitled "ZERO"). In two se…

1.4 Maintenance Method
1.4.9 Lubrication of Linear Guide in Feeder Carriage Section
Grease should be applied every 6 months after the initial month.
••
••
• Preparation for Lubrication
(1) Turn off the power supply to the machine and wipe off old grease
on the rail of the linear guide with a rag.
(2) Prepare the FL- and P-type attachments.
The combination of the U- and P-type attachment can also be
used for lubrication from the front side of the machine.
Fig. 4A85
••
••
• Lubrication Procedure
The linear guide in the feeder carriage section must
be lubricated with the [POWER ON] button on the
operation panel being pressed ("ON" condition).
It is dangerous. Be sure to lubricate alone (without
any other attended personnel).
(1) Press the [UNIT ADJ.] button on the submenu bar that appears after
the [MAINT.] button is selected.
When the [Oil Supply] tab is pressed in the "Fdr Crg" tab sheet, the
following tab sheet appears.
Fig. 4A85-1 "Oil Supply" Tab Sheet
CAUTION
FL Type
P Type
U Type
0509-004 1-69 AIM01ETRP
Note

1.4 Maintenance Method
(2) When the [Start Oil Supply] button is pressed in the "Oil Supply" tab
sheet, the following sheet appears.
Fig. 4A85-2
(3) Press the [ALL] button (entitled "ZERO"). In two seconds, press the
[ENABLE] button on the operation panel. All devices are zeroed.
(4) Press all the buttons (entitled "FEEDER READY").
(5) Press the [ON] button entitled "MOVE". In 2 seconds, press the [EN-
ABLE] button on the operation panel.
All axis automatic tuning takes place and the following sheet ap-
pears. (The feeder carriage moves slightly.)
0305-001 1-70
AIM01ETRP

1.4 Maintenance Method
(6) Press the [ON] button entitled "MOVE". In 2 seconds, press the [EN-
ABLE] button on the operation panel.
The feeder carriage moves to the grease supply position and the
following sheet appears.
Fig. 4A85-3
(7) Press the [EMERGENCY STOP] switch and open all the doors.
Apply grease to the nipples on the slide blocks of linear guides.
After that, close all the doors.
(8) Unlock the [EMERGENCY STOP] switch and press the [RESET]
button. Press the [POWER ON] button to power the machine.
Press the [ALL] button (entitled "ZERO"). In 2 seconds, press the
[ENABLE] button on the operation panel.
0305-001 1-71