1.4 Maintenance Method 1.4.10 Cleaning of Linear Scale Sections T o avoid any malfunction of the feeder carriages, the linear scales and the linear scale encoder heads must be cleaned every three months or whenever the l…

100%1 / 417
1.4 Maintenance Method
(16-3) Press the [ON] button entitled "MOVE". In 2 seconds,
press the [ENABLE] button on the operation panel.
Feeder Carriages #3 and #4 move to the F1 side and the
following sheet appears.
Fig. 4A85-13
(16-4) Press the [Next] button.
When the [ENABLE] button on the operation panel is
pressed in 2 seconds after the [ON] button (entitled
"MOVE"), "2. Move F4 Axis to Ref Mark (-)" is executed.
Follow the same procedure repeatedly and confirm that
the reference marks (Procedure of Operation: 3 through
9) are detected.
0309-002 1-76
AIM01ETRP
1.4 Maintenance Method
1.4.10 Cleaning of Linear Scale Sections
To avoid any malfunction of the feeder carriages, the linear scales and
the linear scale encoder heads must be cleaned every three months
or whenever the linear guides are lubricated.
It is also required to check how the device (the device for which a
reference mark detection is made) works.
Cleaning of Linear Scales
(1) When the [Linear Scale Clean] tab is pressed in the "Fdr Crg" tab
sheet, the following tab sheet appears.
Fig. 4A86-1 "Linear Scale Clean" Tab Sheet
0509-003 1-77
AIM01ETRP
1.4 Maintenance Method
(2) When the [Start Linear Scale Cleaning] button is pressed in the "Linear
Scale Clean" tab sheet, the following sheet appears.
Fig. 4A86-2
(3) Press the [Move Fdr Axis to F1 Origin] button or the [Move Fdr Axis
to F4 Origin] button. In 2 seconds, press the [ENABLE] button on
the operation panel.
The feeder carriage moves toward the specified origin.
(4) Press the [EMERGENCY STOP] switch and open the feeder car-
riage covers.
(5) Clean the linear scales with a cotton swab soaked in alcohol (abso-
lute ethanol).
Never use any organic compounds other than alcohol.
(6) Close all feeder carriage covers.
(7) Turn the [EMERGENCY STOP] switch clockwise to cancel the
emergency stop condition.
(8) Press the [RETURN] button in the "EMERGENCY STOP" window.
0305-001 1-78 AIM01ETRP
Note