4OM-996-007 - 第255页

(0a Feeder Carriage #3) Error ID Item Description 0a0101 Fdr .Crg. Axis Motor #3 Origin Encoder origin was not detected. 0a0102 Fdr .Crg. Axis Motor #3 Origin Origin sensor (slide) was not detected. 0a0104 Fdr .Crg. Axis…

100%1 / 417
3.3 Error IDs and Remedial Procedures
0509-001 2-71-1 AIM01ETRP
Error ID Item Description
090701 Fdr.Crg. Axis Motor #2 Interlock Movement cannot take place until the index angle is adjusted.
090702 Fdr.Crg. Axis Motor #2 Interlock Pallet went out.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
090801 Fdr.Crg. Axis Motor #2 Communication error was detected.
Communication
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
(0a Feeder Carriage #3)
Error ID Item Description
0a0101 Fdr.Crg. Axis Motor #3 Origin Encoder origin was not detected.
0a0102 Fdr.Crg. Axis Motor #3 Origin Origin sensor (slide) was not detected.
0a0104 Fdr.Crg. Axis Motor #3 Origin Feedback value is indefinite.
0a0105 Fdr.Crg. Axis Motor #3 Origin The component pick-up (z) axis is not at origin.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
0a0201 Fdr.Crg. Axis Motor #3 Timing Task has not been completed unable to continue.
0a0301 Fdr.Crg. Axis Motor #3 Data The driver data was detected outside of the possible range.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
0a0401 Fdr.Crg. Axis Motor #3 Limit (+) Limit error has been detected.
0a0402 Fdr.Crg. Axis Motor #3 Limit (-) Limit error has been detected.
0a0403 Fdr.Crg. Axis Motor #3 Limit (+) (-) Limit error has been detected.
(Cause 1) Automatic or manual operation was started without all devices being zeroed after
the machine was powered and the [SYS CLEAR] button was pressed.
(Remedy 1) Press the [
RETURN] button to cancel the error display.
Remove the cause of the error.
Zero all axes and re-start the operation.
0509-002 2-72 AIM01ETRP
3.3 Error IDs and Remedial Procedures
Error ID Item Description
0a0502 Fdr.Crg. Axis Motor #3 User constant breakdown.
Servo Alarm [Shutdown touch sw key and mainbreaker sw off.]
0a0503 Fdr.Crg. Axis Motor #3 Main circuit encoder error
Servo Alarm
0a0504 Fdr.Crg. Axis Motor #3 User constant setting error.
Servo Alarm [Shutdown touch sw key and mainbreaker sw off.]
0a0505 Fdr.Crg. Axis Motor #3 Combination error
Servo Alarm
0a0509 Fdr.Crg. Axis Motor #3 Dividing ratio setting error.
Servo Alarm [Shutdown touch sw key and mainbreaker sw off.]
0a050a Fdr.Crg. Axis Motor #3 Encoder model unmatched.
Servo Alarm [Shutdown touch sw key and mainbreaker sw off.]
0a0510 Fdr.Crg. Axis Motor #3 Overcurrent or Heat Sink Overheated.
Servo Alarm [Shutdown touch sw key and mainbreaker sw off.]
0a0530 Fdr.Crg. Axis Motor #3 Regeneration error detected
Servo Alarm
0a0532 Fdr.Crg. Axis Motor #3 Regenerative overload
Servo Alarm
0a0533 Fdr.Crg. Axis Motor #3 Main circuit power supply wiring error
Servo Alarm
0a0540 Fdr.Crg. Axis Motor #3 Overvoltage
Servo Alarm
0a0541 Fdr.Crg. Axis Motor #3 Undervoltage
Servo Alarm
0a0551 Fdr.Crg. Axis Motor #3 Overspeed
Servo Alarm
0a0555 Fdr.Crg. Axis Motor #3 Linear motors max.speed setting error
Servo Alarm
0a0571 Fdr.Crg. Axis Motor #3 Overload: high load
Servo Alarm
0a0572 Fdr.Crg. Axis Motor #3 Overload: low load
Servo Alarm
0a0573 Fdr.Crg. Axis Motor #3 Dynamic break overload
Servo Alarm
0a0574 Fdr.Crg. Axis Motor #3 Overload of Surge Current Limit Resistor
Servo Alarm [Shutdown touch sw key and mainbreaker sw off.]
0a057a Fdr.Crg. Axis Motor #3 Heat sink overheated
Servo Alarm
0a0581 Fdr.Crg. Axis Motor #3 Encoder backup error.
Servo Alarm [Shutdown touch sw key and mainbreaker sw off.]
0a0582 Fdr.Crg. Axis Motor #3 Encoder checksum error.
Servo Alarm [Shutdown touch sw key and mainbreaker sw off.]
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
0509-002 2-73 AIM01ETRP
3.3 Error IDs and Remedial Procedures