4OM-996-007 - 第33页

Safe-22 AIM01E-P Safety Precautions Feeder Carriage Collision Error Detection Sensors When some feeder carriage collide with each other , these sensors are used to stop the machine. T able 1X6 Sensor Name Symbol Counterm…

100%1 / 417
Safe-21 AIM01E-P
Safety Precautions
Module Protection Sensors
Feeder Installation Error Detection Sensors
When a tape feeder is not installed correctly, these sensors are used to prevent the
machine from being operated.
Table 1X5
Sensor Name Symbol Countermeasures
Installation Error (+) BPX30
Installation Error (-) BPX31
Lifting Prevention (+) SQ2
Lifting Prevention (-) SQ3
Disengaged Latch (+) BPX27
Disengaged Latch (-) BPX28
When one of the left sensors has detected an error,
the following measures are taken.
The power to drive Feeder Carriages #1, #2, #3,
and #4 is shut off.
The rotary turret stops after a cycle of operation.
Ref.: The rotary turret stops with its angle at 0° or
360°.
BPX28
BPX31
SQ3
SQ2
BPX30
BPX27
Rear View (Upper Section)
Fig. 1X22 Feeder Installation Error Detection Sensors
0412-001
Safe-22 AIM01E-P
Safety Precautions
Feeder Carriage Collision Error Detection Sensors
When some feeder carriage collide with each other, these sensors are used to stop the
machine.
Table 1X6
Sensor Name Symbol Countermeasures
Carriage Collision 12 BPH57
Carriage Collision 23 BPH58
Carriage Collision 34 BPH59
When one of the left sensors has detected an error, the fol-
lowing measures are taken.
The power to drive Feeder Carriages #1, #2, #3,
and #4 is shut off.
The rotary turret stops after a cycle of operation.
Ref.: The rotary turret stops with its angle at 0° or 360°.
BPH57
BPH58
BPH59
Top View
Fig. 1X23 Feeder Carriage Collision Error Detection Sensors
0412-001
Safe-23 AIM01E-P
Safety Precautions
X/Y Table P.C.B. Detection Sensors
When a P.C.B. is not positioned correctly on the X/Y table, these sensors are used to stop
the machine.
Table 1X7
Sensor Name Symbol Countermeasures
X/Y Table P.C.B. Detection (Fixed) BPH47
X/Y Table P.C.B. Detection (Movable) BPH49
When one of the left sensors has
detected an error, the following
measures are taken.
The power to drive the X/Y table is
shut off.
The rotary turret stops after a cycle
of operation.
Ref.: The rotary turret stops with its
angle at 0° or 360°.
BPH49
BPH47
Fig. 1X24 Location of X/Y Table P.C.B. Detection Sensors
0412-001