4OM-996-007 - 第335页
Error ID ltem Description 600601 Head Origin Offset T otal Designate Loop Exceeded Time. (Cause 1) Each head deviated from its origin position in comparison with the master head. (Remedy 1) Check if the master head is no…

Error ID ltem Description
600301 Head Bypass Communication Error
600302 Head Bypass Head Origin
600303 Head Bypass Overtime Head Origin Return
600304 Head Bypass Unselected Nozzle Drop
600305 Head Bypass Dummy Nozzle
600306 Head Bypass Manual Bypass
600307 Head Bypass Alarm Error
(Cause 1) Self-Diagnostics Error Message
(Cause 2) The voltage of the stabilization power supply unit (PSU) is abnormal.
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
(Remedy 2) Consult our service personnel for details.
600401 Nozzle Level Nozzle Level (Low) Was More Than Tolerance.
600402 Nozzle Level Nozzle Level (Low) Was Less Than Tolerance.
600403 Nozzle Level Nozzle Level (High) Was More Than Tolerance.
600404 Nozzle Level Nozzle Level (High) Was Less Than Tolerance.
(Cause 1) This error occurs when there is a big difference in nozzle levels in comparison with
the master nozzle during teaching operation.
(Remedy 1) Re-teach the data of the master nozzle.
600501 Master Head Offset Linear Measure System Was At High Position.
600502 Master Head Offset Linear Measure System Was At Low Position.
(Cause 1) The master nozzle or the linear measure detection sensor may not be attached
correctly.
(Remedy 1) Attach the master nozzle correctly.
It is required to adjust the linear measure detection sensor after it is attached
correctly.
0403-002 2-138 AIM01ETRP
3.3 Error IDs and Remedial Procedures

Error ID ltem Description
600601 Head Origin Offset Total Designate Loop Exceeded Time.
(Cause 1) Each head deviated from its origin position in comparison with the master head.
(Remedy 1) Check if the master head is not loose.
600701 Comp. Thickness Teach Component Thickness Was Less Than Tolerance.
600702 Comp. Thickness Teach Component Thickness Was More Than Tolerance.
(Cause 1) A mistake is found in the component thickness data of the component library data.
(Remedy 1) Set the component thickness data correctly.
600801 Recog. Data Teach Recognition Error Code.
600901 Trash Teach
Trash Teach Error Code.
Note: Refer to "4. Troubleshooting on Recognition System (Error ID)" for details.
0305-001 2-139 AIM01ETRP
3.3 Error IDs and Remedial Procedures

(61 Lighting for Component Recognition)
Error ID ltem Description
610101 Nozzle Recog. Recognition Error Code
Note: Refer to "4.3.4 Nozzle Recognition Errors” for the detailed error display.
610201 Nozzle Bypass Nozzle Down Error (L)
610202 Nozzle Bypass Nozzle Down Error (H)
610203 Nozzle Bypass Recognition Teach Error
(Cause 1) When the selected nozzle reached the L or H level during operation, the optical
beam of the sensor was shielded (not received).
The sensor may be defective.
(Remedy 1) Remove the dirt on the nozzle end and insert the nozzle deep inside.
The sensor may be defective. If necessary, replace the sensor with a new one.
Before replacing the sensor, contact our service personnel for some advice.
610204 Nozzle Bypass Teach Error Data
(Cause 1) Dirt and dust adhere to the nozzle and an error is found in the nozzle teaching
operation.
(Remedy 1) Remove dirt and dust from the nozzle end and re-perform the nozzle teaching
operation.
610205 Nozzle Bypass Lighting Check
(Cause 1) The diffusion plate of the nozzle may be dusty and dirty or scratched.
(Remedy 1) Clean the diffusion plate or replace it with a new one.
0509-003 2-140 AIM01ETRP
3.3 Error IDs and Remedial Procedures