4OM-996-007 - 第351页

Error ID ltem Description 640601 Head Origin Offset T otal Designate Loop Exceeded Time. (Cause 1) Each head deviated from its origin position in comparison with the master head. (Remedy 1) Check if the master head is no…

100%1 / 417
Error ID ltem Description
640301 Head Skip Communication Error
640302 Head Skip Head Origin
640303 Head Skip Overtime Head Origin Return
640304 Head Skip Unselected Nozzle Drop
640305 Head Skip Dummy Nozzle
640306 Head Skip Manual Bypass
640307 Head Skip Alarm Error
(Cause 1) Self-Diagnostics Error Message
(Cause 2) The voltage of the stabilization power supply unit (PSU) is abnormal.
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
(Remedy 2) Consult our service personnel for details.
640401 Nozzle Level Nozzle Level (Low) Was More Than Tolerance.
640402 Nozzle Level Nozzle Level (Low) Was Less Than Tolerance.
640403 Nozzle Level Nozzle Level (High) Was More Than Tolerance.
640404 Nozzle Level Nozzle Level (High) Was Less Than Tolerance.
(Cause 1) This error occurs when there is a big difference in nozzle levels in comparison with
the master nozzle during teaching operation.
(Remedy 1) Re-teach the data of the master nozzle.
640501 Master Head Offset Linear Measure System Was At High Position.
640502 Master Head Offset Linear Measure System Was At Low Position.
(Cause 1) The master nozzle or the linear measure detection sensor may not be attached
correctly.
(Remedy 1) Attach the master nozzle correctly.
It is required to adjust the linear measure detection sensor after it is attached
correctly.
0305-001 2-154 AIM01ETRP
3.3 Error IDs and Remedial Procedures
Error ID ltem Description
640601 Head Origin Offset Total Designate Loop Exceeded Time.
(Cause 1) Each head deviated from its origin position in comparison with the master head.
(Remedy 1) Check if the master head is not loose.
640701 Comp. Thickness Teach Component Thickness Was Less Than Tolerance.
640702 Comp. Thickness Teach Component Thickness Was More Than Tolerance.
(Cause 1) A mistake is found in the component thickness data of the component library data.
(Remedy 1) Set the component thickness data correctly.
640801 Recog. Data Teach Recognition Error Code.
640901 Trash Teach Trash Teach Error Code.
640b01 Nozzle Posture Level Nozzle Posture Level Was Less Than Low Limit.
Note: Refer to "4. Troubleshooting after Error Window (Recognition Error ID)” for details.
0509-002 2-155 AIM01ETRP
3.3 Error IDs and Remedial Procedures
(65 Head Origin Offset)
Error ID ltem Description
650101 Nozzle Recog. Recognition Error Code
Note: Refer to "4.3.4 Nozzle Recognition Errors" for the detailed error display.
650201 Nozzle Bypass Nozzle Down Error (L)
650202 Nozzle Bypass Nozzle Down Error (H)
650203 Nozzle Bypass Recognition Teach Error
(Cause 1) When the selected nozzle reached the L or H level during operation, the optical
beam of the sensor was shielded (not received).
The sensor may be defective.
(Remedy 1) Remove the dirt on the nozzle end and insert the nozzle deep inside.
The sensor may be defective. If necessary, replace the sensor with a new one.
Before replacing the sensor, contact our service personnel for some advice.
650204 Nozzle Bypass Teach Error Data
(Cause 1) Dirt and dust adhere to the nozzle and an error is found in the nozzle teaching
operation.
(Remedy 1) Remove dirt and dust from the nozzle end and re-perform the nozzle teaching
operation.
650205 Nozzle Bypass Lighting Check
(Cause 1) The diffusion plate of the nozzle may be dusty and dirty or scratched.
(Remedy 1) Clean the diffusion plate or replace it with a new one.
0509-003 2-156 AIM01ETRP
3.3 Error IDs and Remedial Procedures