4OM-996-007 - 第362页

Error ID ltem Description 670301 Head Skip Communication Error 670302 Head Skip Head Origin 670303 Head Skip Overtime Head Origin Return 670304 Head Skip Unselected Nozzle Drop 670305 Head Skip Dummy Nozzle 670306 Head S…

100%1 / 417
Error ID ltem Description
670206 Nozzle Bypass Nozzle Level
(Cause 1) This error occurs when the L value exceeds the tolerance in comparison with the
master nozzle in the offset data.
(Remedy 1) Check if a big value is set as an L level of the master level in the offset data.
Check if the nozzle is broken or dirt adheres to the end.
670207 Nozzle Bypass Nozzle Drop
(Cause 1) The nozzle being used has dropped.
(Remedy 1) Check the pertinent nozzle.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
670208 Nozzle Bypass Dummy Nozzle
670209 Nozzle Bypass Manual Bypass
(Cause 1) This appears when some nozzles are bypassed manually.
(Remedy 1) When the [Reset Noz. Bypass] button is pressed in the "Head/Noz. Bypass" tab
sheet of the "OPN. MODE" window (submenu), the manual bypass designation
of all nozzles is all canceled.
67020a Nozzle Bypass Nozzle Change Error. (Cam lock action)
67020b Nozzle Bypass Nozzle Change Error. (Cam Free action)
67020c Nozzle Bypass Cam Origin Error.
67020d Nozzle Bypass Nozzle Teach Error.
67020e Nozzle Bypass Nozzle Posture Detection
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
0509-003 2-165 AIM01ETRP
3.3 Error IDs and Remedial Procedures
Error ID ltem Description
670301 Head Skip Communication Error
670302 Head Skip Head Origin
670303 Head Skip Overtime Head Origin Return
670304 Head Skip Unselected Nozzle Drop
670305 Head Skip Dummy Nozzle
670306 Head Skip Manual Bypass
670307 Head Skip Alarm Error
(Cause 1) Self-Diagnostics Error Message
(Cause 2) The voltage of the stabilization power supply unit (PSU) is abnormal.
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
(Remedy 2) Consult our service personnel for details.
670401 Nozzle Level Nozzle Level (Low) Was More Than Tolerance.
670402 Nozzle Level Nozzle Level (Low) Was Less Than Tolerance.
670403 Nozzle Level Nozzle Level (High) Was More Than Tolerance.
670404 Nozzle Level Nozzle Level (High) Was Less Than Tolerance.
(Cause 1) This error occurs when there is a big difference in nozzle levels in comparison with
the master nozzle during teaching operation.
(Remedy 1) Re-teach the data of the master nozzle.
670501 Master Head Offset Linear Measure System Was At High Position.
670502 Master Head Offset Linear Measure System Was At Low Position.
(Cause 1) The master nozzle or the linear measure detection sensor may not be attached
correctly.
(Remedy 1) Attach the master nozzle correctly.
It is required to adjust the linear measure detection sensor after it is attached
correctly.
0305-001 2-166 AIM01ETRP
3.3 Error IDs and Remedial Procedures
0509-002 2-167 AIM01ETRP
Error ID ltem Description
670601 Head Origin Offset Total Designate Loop Exceeded Time.
(Cause 1) Each head deviated from its origin position in comparison with the master head.
(Remedy 1) Check if the master head is not loose.
670701 Comp. Thickness Teach Component Thickness Was Less Than Tolerance.
670702 Comp. Thickness Teach Component Thickness Was More Than Tolerance.
(Cause 1) A mistake is found in the component thickness data of the component library data.
(Remedy 1) Set the component thickness data correctly.
670801 Recog. Data Teach Recognition Error Code.
670901 Trash Teach Trash Teach Error Code.
670b01 Nozzle Posture Level Nozzle Posture Level Was Less Than Low Limit.
Note: Refer to "4. Troubleshooting after Error Window (Recognition Error ID)" for details.
3.3 Error IDs and Remedial Procedures
(Pages 2-168 through 2-179 omitted intentionally)