4OM-996-007 - 第388页

Recognition Error ID Recognition Error Contents, Cause, and Remedy 02**3400** Error in Line Detection 02**3401** Some linear edges cannot be detected because they are hidden by the nozzle. 02**3402** No lin ear edge dete…

100%1 / 417
Recognition Error ID Recognition Error Contents, Cause, and Remedy
02**3300** Error in Edge Detection
02**3301** Some edges cannot be detected because
they are hidden by the nozzle.
02**3302** No Edge Detected.
02**3303** Upper Edge Not Detected.
02**3304** Left Edge Not Detected.
02**3305** Lower Edge Not Detected.
02**3306** Right Edge Not Detected.
(Cause 1) The selected component does not match the nozzle.
(Cause 2) Wrong parameters (edge data) are set for the selected component in the
component library data.
(Cause 3) The tapered part of the vacuum nozzle end or the diffusion plate is stained.
Fig. 4B25
(Remedy 1) Check the selected component and the vacuum nozzle.
Check if the feeder (B) offset data is correct.
(Remedy 2) Check the edge condition of the selected component and the compo-
nent library data.
If wrong parameters are set in the component library data, correct them.
(Remedy 3) Clean the vacuum nozzle end or the diffusion plate.
Component
Vacuum Nozzle
Dirty Spots
4.3 Recognition Error IDs and Remedial Procedures
0509-002 2-203 AIM01ETRP
Recognition Error ID Recognition Error Contents, Cause, and Remedy
02**3400** Error in Line Detection
02**3401** Some linear edges cannot be detected because they are hidden by the nozzle.
02**3402** No linear edge detected.
02**3403** The detected linear edge position does not match the position data.
(Cause 1) There is a difference between the results of the line inspection of the se-
lected component and the component library data.
(Remedy 1) Check the line of the selected component and the component library
da
ta. If wrong parameters are set in the component library data, correct
them.
02**3500** Error in Lead Detection
02**3501** Some leads cannot be detected because they are hidden by the nozzle.
02**3502** No Lead Detected.
02**3503** Corner of Leads Not Detected.
02**3504** Ends of Leads Not Detected.
02**3505** Ends of Arrayed Leads Not Detected.
02**3506** Lead Edges of Corner Not Detected.
02**3507** Leads of Corner Not Detected.
02**3508** The number of leads at the detected corner is smaller than the set value.
02**3509** Incorrect Lead-to-Lead Distance at Detected Corner.
02**3510** Incorrect Lead-to-Lead Angle at Detected Corner.
02**3512** The detected number of leads is smaller than the set value.
02**3513** The detected number of leads is larger than the set value.
02**3515** The detected lead position does not match the position data.
(Cause 1) The results of the lead detection differ from the parameters specified in the
component library data for the selected components.
(Remedy 1) Check the leads of the selected component and the component library
data.
If wrong parameters are set in the component library data, correct them.
4.3 Recognition Error IDs and Remedial Procedures
0509-002 2-204 AIM01ETRP
4.3 Recognition Error IDs and Remedial Procedures
Recognition Error ID
Recognition Error Contents, Cause, and Remedy
02**3600** Error in Electrode(ball) Detection
02**3601** No Electrode(ball) Detected.
02**3602** Since a sufficient number of Electrode(ball) were undetectable, it cannot position.
02**3603** There is Electrode(ball) undetectable in the line or sequence of a group outside.
02**3604** Electrode(ball) which is in agreement with data was undetectable.
02**3605** Electrode(ball) which is not specified was detected.
(Cause 1) There is a difference between the results of the electrode (ball) inspection
of the selected component and the component library data.
(Remedy 1) Check the electrodes (balls) of the selected component and the compo-
nent library data.
Correct wrong parameters if they are set in the component library
data.
02**4100** Reverse Check Error
02**4101** The component is reversed.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Contact our service personnel for details.
02**4200** Error in Pick-up Position Detection
02**4201** The pick-up position has deviated greatly in X direction.
02**4202** The pick-up position has deviated greatly in Y direction.
02**4203** The pick angular skew is big.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Contact our service personnel for details.
0509-002 2-205 AIM01ETRP