4OM-996-007 - 第51页

Safe-40 AIM01E-P Safety Precautions T able 1X17 No. Alert Labels and Description *28 Description z Never perform the automatic operation with the feeder carriage cover(s) and the feeder work area safety door(s) being kep…

100%1 / 417
Safe-39 AIM01E-P
Safety Precautions
Table 1X16
No. Alert Labels and Description
*26
Description
z Install the feeders correctly. Otherwise, the machine and feeders may break down.
*27
Description
z This machine uses fluorocarbon as a refrigerant.
This product must be abandoned by the purchaser according to related laws in
local area.
z The type and quantity of the fluorocarbon are described on the "Service Valve"
name plate.
Type Chemical Formula Quantity (g)
R407C HFC-32/125/134a 780
0502-002
Safe-40 AIM01E-P
Safety Precautions
Table 1X17
No. Alert Labels and Description
*28
Description
z Never perform the automatic operation with the feeder carriage cover(s) and the
feeder work area safety door(s) being kept open.
z Never modify the [EMERGENCY STOP] switches, the safety doors, etc.
z Do not put your hand or head in the moving ranges of the machine during
operation.
z Only trained personnel should be allowed to operate the machine.
z Operate the machine with the covers being attached.
z In principle, only one person should operate the machine.
0502-002
Safe-41 AIM01E-P
Safety Precautions
5. Precautionary Items for Correct Operations
Requirements for Installation
Be sure to fulfill the following requirements for safety purposes.
Overvoltage Category : Category III
Pollution Degree : 3
z Overvoltage Categories refer to the level of Impulse Withstand Voltage protection
provided at the specified Pollution Degree.
Category III : Primary circuits of a device to which power is directly
supplied from the power distribution panel, and circuits from
the distribution panel to outlets.
The term was changed from "Installation Category" to "Overvoltage
Category".
z "Pollution Degree" is a degree of pollution severity.
Pollution Degree 3: Conductive pollution or dry nonconductive pollution
that becomes conductive due to condensation occurs.
To be found in industrial environment or construction
sites (harsh environments).
Note
0502-002