0509-002 1-27 AIM01ETRP 1.3 Maintenance Spots Linear Scale Linear Scale/Encoder Head 3M7-2 Every 3 Months Cleaning Clean the linear scales and encoder heads every three months or every time the linear guides are lubricat…

100%1 / 417
(13) Feeder Carriage Section
1.3 Maintenance Spots
0509-003 1-26 AIM01ETRP
Fig. 4A28 Top View of Machine
Do not bring any metal of high magnetizability close
to this. Otherwise, such metal will easily be magne-
tized and attracted, causing an injury to the opera-
tor and/or a mechanical breakdown.
Do not bring any magnetizable material close to this.
Those who wear implanted pacemakers should not
work inside the machine. Otherwise, the pacemaker
may be affected by magnetism, leading to a serious
accident.
CAUTION
WARNING
Linear Guide Rails 1M13
Every Month Cleaning
Clean the carriage with an oiled rag.
Yoke Sides of Linear Motors 1M13-1
Every Month Inspection/Cleaning
Check for components and/or foreign substances
adhered to the yoke sides of the linear motors. If neces-
sary, clean the yoke sides with a rag.
Refer to "1.4.11 Cleaning of Linear Motor's Yoke Sides"
for details.
0509-002 1-27 AIM01ETRP
1.3 Maintenance Spots
Linear Scale
Linear Scale/Encoder Head 3M7-2
Every 3 Months Cleaning
Clean the linear scales and encoder heads every three months or every time the linear guides are
lubricated.
Refer to "1.4.10 Cleaning of Linear Scale Sections" for details.
Encoder Head
Fig. 4A28-1 Front View of Machine
Fig. 4A29 Front View of Machine
1.3 Maintenance Spots
0509-003 1-28 AIM01ETRP
Grease Nipples
Magnified View of Feeder Carriage
Slide Block of Linear Guide
Slide Block of Linear Guide (Front Side) 6M4
Every 6 Months Lubrication (DAPHNE EPONEX GREASE No. 1)
Grease should be applied every 6 months after the initial month.
* Use the FL- and P-type or the U- and P-type attachments.
Refer to "1.4.9 Lubrication of Linear Guide in Feeder Carriage Section" for details.
P Type