4OM-1505-004_w.pdf - 第133页

4OM-1505 2-18 2. T roubleshooting on Each Section : Chap.2 (04 Stencil-Y Axis) T4B15 Error ID Error Name, Description, Cause, and Remedy 0401000 Stencil-Y Origin Zeroing opn. was incompleted, within specied time. (Cause…

100%1 / 181
4OM-1505
2-17
2. Troubleshooting on Each Section : Chap.2
0906-001
Error ID Error Name, Description, Cause, and Remedy
0315000 Table-
θ
Timing
Task has not been completed unable to continue.
0316000 Table-
θ
Data
The data was detected outside of the possible range.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and restart the operation. If the machine is not reset to its
normal condition, shut down the power of the machine once and power up
the machine again. After that, restart the operation. When the same error still
occurs, contact our service personnel for details.
0318000 T
able-
θ
Overrun
Limit error has been detected.
(Cause 1) Dirt adheres to the sensor and the optical beam is shielded.
(Cause 2) The sensor is defective.
(Cause 3) The
driver is malfunctioning or an error has occurred during communication with
the host CPU.
(Remedy 1) Wipe off dirt on the sensor and zero the table
θ
axis again.
(Remedy 2) It is required to replace the sensor with a new one. Contact our service
personnel for details.
(Remedy 3) Shut down the power of the machine once and power up the machine again.
After that, zero the table
θ
axis. If this operation does not reset the machine
to its normal condition, the driver may be defective. Contact our service
personnel for details.
T4B14
4OM-1505
2-18
2. Troubleshooting on Each Section : Chap.2
(04 Stencil-Y Axis)
T4B15
Error ID Error Name, Description, Cause, and Remedy
0401000 Stencil-Y Origin
Zeroing opn. was incompleted, within specied time.
(Cause 1) Dirt adheres to the sensor and the optical beam is shielded.
(Cause 2) The sensor (B291) is defective.
(Cause 3) The
driver is malfunctioning or an error has occurred during communication with
the host CPU.
(Remedy 1) Wipe off dirt on the sensor and zero the stencil Y again.
(Remedy 2)
It is required to replace the sensor with a new one. Contact our service
personnel for details.
(Remedy 3) Shut down the power of the machine once and power up the machine again.
After that, zero the stencil Y. If this operation does not reset the machine to its
normal condition, the driver may be defective. Contact our service personnel
for details.
0402000 Stencil-Y Origin
Detect lost pulse error.
(Cause 1) The motor is overloaded and has a loss of synchronism.
(Remedy 1) Check for any obstacle around
the stencil Y axis and then perform the zeroing
operation. If this operation does not reset the machine to its normal condition,
contact our service personnel for details.
0404000 Stencil-Y Origin
(-) Limit error has been detected.
(Cause 1) Dirt adheres to the sensor and the optical beam is shielded.
(Cause 2) The sensor (B293) is defective.
(Cause 3) The
driver is malfunctioning or an error has occurred during communication with
the host CPU.
(Remedy 1) Wipe off dirt on the sensor and zero Stencil-Y again.
(Remedy 2) It is required to replace the sensor with a new one. Contact our service
personnel for details.
(Remedy 3)
Shut down the power of the machine once and power up the machine again.
After that, zero Stencil-Y. If this operation does not reset the machine to its
normal condition, the driver may be defective. Contact our service personnel
for details.
0405000 Stencil-Y Driver
Driver alarm signal was detected.
0408000 Stencil-Y Driver
Driver Over-Heat
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and restart the operation. If this operation does not reset the
machine to its normal condition, contact our service personnel for details.
0906-001
4OM-1505
2-19
2. Troubleshooting on Each Section : Chap.2
0906-001
T4B16
Error ID Error Name, Description, Cause, and Remedy
0411000 Stencil-Y Interlock
Table-Z Axis is not at safety area.
(Cause 1) The table Z axis interlock sensor (B4C) is defective.
(Cause 2) The operation timing is shifted from the normal one.
(Cause 3) The stencil Y axis was activated after the table Z axis had moved up. (during
the manual operation)
(Remedy 1) Check how the sensor is working in "DEVICE CHECK" window.
When the sensor is not working, it is required to replace the sensor with a
new one. Contact our service personnel for details.
(Remedy 2) Shut down the power of the machine once and power up the machine again.
After that, restart the operation. When the same error still occurs, contact our
service personnel for details.
(Remedy 3)
Perform the zeroing operation and restart the operation.
0414000 Stencil-Y Timing
Task has not been completed unable to continue.
0415000 Stencil-Y Data
The data was detected outside of the possible range.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and restart the operation. If the machine is not reset to its
normal condition, shut down the power of the machine once and power up
the machine again. After that, restart the operation. When the same error still
occurs, contact our service personnel for details.
0416000 Stencil-Y Origin
Zeroing Opn. Not Complete.
(Cause 1) The motor axis was activated before the zeroing operation was completed.
(Remedy 1) Perform the zeroing operation.