4OM-1505 2-36 2. T roubleshooting on Each Section : Chap.2 (13 PCB Transfer) T4B33 Error ID Error Name, Description, Cause, and Remedy 1301000 PCB Supply PCB transfer signal was not offed after PCB detect. 1302000 PCB Su…

100%1 / 181
4OM-1505
2-35
2. Troubleshooting on Each Section : Chap.2
(12 Output Conveyor)
T4B32
Error ID Error Name, Description, Cause, and Remedy
1201000 Output Conveyor Width Origin
Zeroing opn. was incompleted, within specied time.
(Cause 1) Dirt adheres to the sensor and the optical beam is shielded.
(Cause 2) The sensor (B391) (Right ow
B371) is defective.
(Cause 3) The d
river is malfunctioning or an error has occurred during communication with
the host CPU.
(Remedy 1) Wipe off the dirt on the sensor and zero the output conveyor width axis again.
(Remedy 2) It is required to replace the sensor with a new one. Contact our service
personnel for details.
(Remedy 3) Shut down the power of the machine once and power up the machine again.
After that, zero the output conveyor width axis. If this operation does not reset
the machine to its normal condition, the driver may be defective. Contact our
service personnel for details.
1202000 Output Conveyor Width Origin
Detect lost pulse error.
(Cause 1) The motor is overloaded and has a loss of synchronism.
(Remedy 1) Check for any obstacle around the output conveyor width axis and perform
the zeroing operation. If this operation does not reset the machine to its
normal condition, contact our service personnel for details.
1205000 Output Conveyor Width Driver
Driver alarm signal was detected.
1208000 Output Conveyor Width Driver
Driver Over-Heat
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and restart the operation. If this operation does not reset the
machine to its normal condition, contact our service personnel for details.
1211000 Output Conveyor Width Interlock
PCB was exist on conveyor.
(Cause 1)
No operation is possible because a PCB still exists on the conveyor.
(Cause 2) The PCB detection sensors (B44 and B45) are defective.
(Remedy 1) Remove the PCB and restart the operation.
(Remedy 2) Check how the sensors are working in "DEVICE CHECK" window.
When the sensors are not working, it is required to replace the sensors with
new ones. Contact our service personnel for details.
1212000 Output Conveyor Width Data
The data was detected outside of the possible range.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and restart the operation. If the machine is not reset to its
normal condition, shut down the power of the machine once and power up
the machine again. After that, restart the operation. When the same error still
occurs, contact our service personnel for details.
1213000 Output Conveyor Width Origin
Zeroing Opn. Not Complete.
(Cause 1) The motor axis was activated before the zeroing operation was completed.
(Remedy 1) Perform the zeroing operation.
0906-001
4OM-1505
2-36
2. Troubleshooting on Each Section : Chap.2
(13 PCB Transfer)
T4B33
Error ID Error Name, Description, Cause, and Remedy
1301000 PCB Supply
PCB transfer signal was not offed after PCB detect.
1302000 PCB Supply
PCB transfer signal is off before PCB detect.
(Cause 1) Communication Error with Input Machine
(Remedy 1) Check the PCB transfer signal from the input machine in the "Org./Signal
Info." window. When the problem cannot be solved, contact our service
personnel for details.
1303000 Input Conveyor T
ime Over
PCB from inp. machine was not received within specied time.
(Cause 1) The set value of the timer is too short.
(Cause 2) The conveyor speed is too slow.
(Cause 3) The PCB detection sensor (B41) is not working.
(Remedy 1) Set a larger parameter in the "Output Conveyor" text box of the "Timer Setting
(sec)" group box in the "Transfer Mode" window.
(Remedy 2)
Set a larger parameter in the “PCB Input Speed” data box in the "Conveyor
Transfer" window.
(Remedy 3) Check how the sensor is working in "DEVICE CHECK" window
.
When the sensor is not working, it is required to adjust the sensor position or
replace the sensor with a new one. Contact our service personnel for details.
1304000 Output Conveyor Time Over
PCB was not transfered to outp.conv. within specied time.
(Cause 1) The set value of the timer is too short.
(Cause 2) Communication Error with Output Machine
(Remedy 1) Set a larger parameter in the "Output Conveyor" text box of the "Timer Setting
(sec)" group box in the "Transfer Mode" window.
(Remedy 2)
Contact our service personnel for details.
1305000 PCB Transfer T
ime Over
PCB transfer from inp. conv. was not completed within specied time.
(Cause 1) The conveyor speed is too slow.
(Cause 2) The PCB detection sensor (B71) is not working.
(Remedy 1) Set a larger parameter in the "PCB transfer speed" in the "Conveyor Transfer"
window.
(Remedy 2)
Check how the sensor is working in "DEVICE CHECK" window.
When the sensor is not working, it is required to adjust the sensor position or
replace the sensor with a new one. Contact our service personnel for details.
1306000 PCB T
ransfer Time Over
PCB transfer to outp.conv. was not completed within specied time.
(Cause 1) The PCB arrival check sensor (B44) is not working.
(Remedy 1) Check how the sensor is working in "DEVICE CHECK" window.
When the sensor is not working, it is required to adjust the sensor position or
replace the sensor with a new one. Contact our service personnel for details.
0906-001
4OM-1505
2-37
2. Troubleshooting on Each Section : Chap.2
0906-001
T4B34
Error ID Error Name, Description, Cause, and Remedy
1307000 PCB Transfer Time Over
PCB was not transfered from outp.conv. within specied time.
(Cause 1) The PCB passage check sensor (B45) is not set in the E/NR (Light Emitted and
Not Received) or the E/R (Light Emitted and Received) mode.
(Remedy 1) Check how the sensor is working in "DEVICE CHECK" window.
When the sensor is not working, it is required to adjust the sensor position or
replace the sensor with a new one. Contact our service personnel for details.
1308000 PCB T
ransfer Time Over
PCB transfer to input conv. was not completed within specied time.
(Cause 1) The PCB detection sensor (B41) is not set in the E/NR (Light Emitted and Not
Received) or the E/R (Light Emitted and Received) mode.
(Cause 2) The conveyor speed is too slow.
(Remedy 1) Check how the sensor is working in "DEVICE CHECK" window.
When the sensor is not working, it is required to adjust the sensor position or
replace the sensor with a new one. Contact our service personnel for details.
(Remedy 2) T
urn up the variable resistor of the L conveyor speed control.
1309000 Input Conveyor Interlock
PCB Backup axis was up.
1310000 Output Conveyor Interlock
PCB Backup axis was up.
(Cause 1) Dirt adheres to the backup axis near origin sensor and the optical beam is
shielded.
(Cause 2) The backup axis near origin sensor is defective.
(Cause 3) The backup axis driver is malfunctioning or an error has occurred during
communication with the host CPU.
(Remedy 1) Wipe off the dirt on the sensor and zero the PCB backup axis again.
(Remedy 2) It is required to replace the sensor with a new one. Contact our service
personnel for details.
(Remedy 3) Shut down the power of the machine once and power up the machine again.
After that, zero the PCB backup axis. If this operation does not reset the
machine to its normal condition, the driver may be defective. Contact our
service personnel for details.
1312000
PCB Transfer Interlock
Input Conveyor motor was running.
1313000 PCB Transfer Interlock
Output conveyor motor was running.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Shut down the power of the machine once and power up the machine again.
After that, restart the operation. When the same error still occurs, contact our
service personnel for details.