4OM-1505-004_w.pdf - 第157页
4OM-1505 2-42 2. T roubleshooting on Each Section : Chap.2 (15 Safety Device) T4B39 Error ID Error Name, Description, Cause, and Remedy 1501000 Load Power Of f [Emergency] switch pressed. (Cause 1) An [EMERGENCY STOP] sw…

4OM-1505
2-41
2. Troubleshooting on Each Section : Chap.2
0906-001
T4B38
Error ID Error Name, Description, Cause, and Remedy
1409000 Printing Pressure Assign
Printing pressure exceeded upper range. (Peak)
(Cause 1) The printing pressure was not constant temporarily.
(Cause 2) The output value of the load cell is abnormal.
(Remedy 1) Check for any foreign substances on the production PCB and the stencil.
(Remedy 2) Check for any foreign substances near the load cell. When the same error still
occurs, contact our service personnel for details.
1410000
Squeegee Up/Down Interlock
Squeegee up/down cylinder. Squgeg.Y axis was not at safety area.
(Cause 1) The range of the squeegee movement has exceeded the limited one.
(Remedy 1) Check if the parameters in the "Origin [mm]" and "Depth" text boxes of "Print
Area" in the "PCB Data" window and the parameters in the "Paste Size" and
"Print Margin" group boxes in the "Printing Condition" window are too large or
not.
1412000 Squeegee Up/Down Interlock
Squeegee up/down cylinder. PCB was not checked.
(Cause 1) The squeegee was moved down when a PCB was not clamped on the table.
(during the manual operation)
(Remedy 1) Clamp the PCB in the table section and move up the table. After that, restart
the operation.

4OM-1505
2-42
2. Troubleshooting on Each Section : Chap.2
(15 Safety Device)
T4B39
Error ID Error Name, Description, Cause, and Remedy
1501000 Load Power Off
[Emergency] switch pressed.
(Cause 1) An [EMERGENCY STOP] switch was pressed.
(Remedy 1) Unlock the [EMERGENCY ST
OP] switch and hold down the [POWER ON]
button on the operation panel for more than 3 seconds. After that, press the
[RETURN] button in the "ERROR" window.
1502000 Load Power Off
The air pressure is too low.
(Cause 1) The main air pressure had dropped below 0.4MPa (the set value of the
pressure switch).
(Remedy 1) Adjust the pressure to the correct one.
1503000 Load Power Off
The safety door is open.
(Cause 1) The transparent cover is open.
(Remedy 1) Close the transparent cover and hold down the [POWER ON] button on the
operation panel for more than 3 seconds. After that, press the [RETURN]
button on the touch screen. Power up the machine again and restart the
operation.
1504000 Load Power Off
Detected circuit breaker of
f.
(Cause 1) The circuit breaker of Q100, Q202 or Q203 is turned OFF.
(Remedy 1) Contact our service personnel for details.
1505000 Load Power Off
Detected all load power moniter of
f.
(Cause 1) The load power supply monitor (K021) is turned OFF.
(Remedy 1) Shut down the power of the machine once and power up the machine again.
After that, restart the operation. When the same error still occurs, contact our
service personnel for details.
1506000 Load Power Off
Detected load power moniter of
f.
(Cause 1) The load power supply monitor (K15) is turned OFF.
(Remedy 1) Shut down the power of the machine once and power up the machine again.
After that, restart the operation. When the same error still occurs, contact our
service personnel for details. If possible, check how the fuse (F01), K03, K15,
K2020 and K204 are working.
0906-001

4OM-1505
2-43
2. Troubleshooting on Each Section : Chap.2
(16 Self-Diagnostics)
T4B40
Error ID Error Name, Description, Cause, and Remedy
1601000 Control Board
System error
1602000 Control Board
Control board error
(Cause 1) An error has occurred in the I/O communication.
(Remedy 1) Shut down the power of the machine once and power up the machine again.
After that, restart the operation. When the same error still occurs, contact our
service personnel for details.
1603000 Sensor
Paste detect sensor error
(Cause 1) The paste height detection sensor (B64) is not adjusted correctly.
(Remedy 1) Contact our service personnel for details.
1604000 System Error
Undened Error.
1605000 System Error
Illegal error code.
1606000 System Error
Internal data error.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1)
Shut down the power of the machine once and power up the machine again.
After that, restart the operation. When the same error still occurs, contact our
service personnel for details.
1607000 System Error
Failed to caliculate position.
(Cause 1) Self-Diagnostics Error Message
(Cause 2) The amount of the recognition correction has exceeded the limited value
(10 mm twice).
(Remedy 1) Shut down the power of the machine once and power up the machine again.
After that, restart the operation. When the same error still occurs, contact our
service personnel for details.
(Remedy 2) Check the coordinates of the ducial mark and the value for printing
inaccuracy correction.
0906-001