4OM-1505 2-49 2. T roubleshooting on Each Section : Chap.2 0906-001 T4B46 Error ID Error Name, Description, Cause, and Remedy 1801038 PEC Recog. #1 Unavailable ducial mark polality was set. 1801040 PEC Recog. #1 Unavail…

4OM-1505
2-48
2. Troubleshooting on Each Section : Chap.2
0906-001
T4B45
Error ID Error Name, Description, Cause, and Remedy
1801029 PEC Recog. #1
Image around ducial mark was unstable.
1801030 PEC Recog. #1
Error of mark gure similitude was extensive.
1801031 PEC Recog. #1
Error of mark similitude or mark size was extensive.
1801032 PEC Recog. #1
Specied mark was not found in window of recog.monitor.
(Cause 1) The ducial marks do not conform to the coordinates X and Y of the ducial
marks or the recognition mark data in the pattern program.
(Remedy 1) Follow the steps below to reset the machine to the normal condition.
(1) When the [RETURN] button is pressed, the following window opens.
(2) When the actual ducial mark is out of the recognition area, move the
camera such that the mark can enter the recognition area. Select the
[Manual Alignment [ST
ART]] button and press one of the arrow buttons
in the "DIRECTION" and one of the "SPEED" buttons. While the [START]
button is being pressed, the camera keeps on moving.
(3) Select the [Retry Recog. [START]] button and press the [START] button.
When the recognition is completed successfully, this window automatically
closes.
(4) When the recognition still failed after the re-recognition operation, move
the camera such that the actual ducial mark can stay at the ducial mark
template (located at the center of the cross hair).
Note
Be sure to adjust the position of the ducial mark as accurately
as possible because the printing accuracy is affected by this
adjustment.
(5) Select the [Man. Align. nished [START]] button and press the [START]
button. The original window resumes.
Note
If the [STOP] button is pressed while the "Manual Alignment"
window is active, the processing is interrupted and the original
window resumes.
F4B5

4OM-1505
2-49
2. Troubleshooting on Each Section : Chap.2
0906-001
T4B46
Error ID Error Name, Description, Cause, and Remedy
1801038 PEC Recog. #1
Unavailable ducial mark polality was set.
1801040 PEC Recog. #1
Unavailable ducial mark area was set.
1801043 PEC Recog. #1
Recognition system error.
1801056 PEC Recog. #1
Recog. transaction time over.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Shut down the power of the machine once and power up the machine again.
After that, restart the operation. When the same error still occurs, contact our
service personnel for details.
1802000 PEC Recog. #2
1802001 PEC Recog. #2
[Camera ID] exceeds the range of setting.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1)
Zero all axes and restart the operation. If the machine is not reset to its
normal condition, shut down the power of the machine once and power up
the machine again. After that, restart the operation. When the same error still
occurs, contact our service personnel for details.
1802003 PEC Recog. #2
[Camera Gain] exceeds the range of setting.
1802004
PEC Recog. #2
[Camera Level] exceeds the range of setting.
1802011 PEC Recog. #2
[Mark Size D1] exceeds the range of setting.
1802012 PEC Recog. #2
[Mark Size D2] exceeds the range of setting.
1802014 PEC Recog. #2
[Mark Judge Level] exceeds the range of setting.
(Cause 1) The data has exceeded the allowable range.
(Remedy 1) Set correct parameters.
1802029 PEC Recog. #2
Image around ducial mark was unstable.
1802030 PEC Recog. #2
Error of mark gure similitude was extensive.
1802031 PEC Recog. #2
Error of mark similitude or mark size was extensive.
1802032
PEC Recog. #2
Specied mark was not found in window of recog.monitor.
(Cause 1) The ducial marks do not conform to the coordinates X and Y of the ducial
marks or the recognition mark data in the pattern program.
(Remedy 1) Follow the steps below to reset the machine to the normal condition. Refer to
"Error ID "1801032"" for details.

4OM-1505
2-50
2. Troubleshooting on Each Section : Chap.2
0906-001
T4B47
Error ID Error Name, Description, Cause, and Remedy
1802038 PEC Recog. #2
Unavailable ducial mark polality was set.
1802040 PEC Recog. #2
Unavailable ducial mark area was set.
1802043 PEC Recog. #2
Recognition system error.
1802056 PEC Recog. #2
Recog. transaction time over.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Shut down the power of the machine once and power up the machine again.
After that, restart the operation. When the same error still occurs, contact our
service personnel for details.
1804000 PEC Recog. T
est
1804001 PEC Recog. Test
[Camera ID] exceeds the range of setting.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and restart the operation. If the machine is not reset to its
normal condition, shut down the power of the machine once and power up
the machine again. After that, restart the operation. When the same error still
occurs, contact our service personnel for details.
1804003 PEC Recog.
Test
[Camera Gain] exceeds the range of setting.
1804004 PEC Recog. Test
[Camera Level] exceeds the range of setting.
1804011 PEC Recog. Test
[Mark Size D1] exceeds the range of setting.
1804012 PEC Recog. Test
[Mark Size D2] exceeds the range of setting.
1804014 PEC Recog. Test
[Mark Judge Level] exceeds the range of setting.
(Cause 1) The data has exceeded the allowable range.
(Remedy 1) Set correct parameters.
1804029 PEC Recog. Test
Image around ducial mark was unstable.
1804030
PEC Recog. Test
Error of mark gure similitude was extensive.
1804031 PEC Recog. Test
Error of mark similitude or mark size was extensive.
1804032 PEC Recog. Test
Specied mark was not found in window of recog.monitor.
(Cause 1) The ducial marks do not conform to the coordinates X and Y of the ducial
marks or the recognition mark data in the pattern program.
(Remedy 1) Follow the steps below to reset the machine to the normal condition. Refer to
"Error ID "1801032"" for details.