4OM-1505
2-52
2. Troubleshooting on Each Section : Chap.2
0906-001
T4B49
Error ID Error Name, Description, Cause, and Remedy
1806038 PEC Recog. Camera
Unavailable ducial mark polality was set.
1806040 PEC Recog. Camera
Unavailable ducial mark area was set.
1806043 PEC Recog. Camera
Recognition system error.
1806056 PEC Recog. Camera
Recog. transaction time over.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Shut down the power of the machine once and power up the machine again.
After that, restart the operation. When the same error still occurs, contact our
service personnel for details.
1807000 Recog. T
ransaction
1807001 Recog. Transaction
[Camera ID] exceeds the range of setting.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and restart the operation. If the machine is not reset to its
normal condition, shut down the power of the machine once and power up
the machine again. After that, restart the operation. When the same error still
occurs, contact our service personnel for details.
1807003 Recog.
Transaction
[Camera Gain] exceeds the range of setting.
1807004 Recog. Transaction
[Camera Level] exceeds the range of setting.
1807011 Recog. Transaction
[Mark Size D1] exceeds the range of setting.
1807012 Recog. Transaction
[Mark Size D2] exceeds the range of setting.
1807014 Recog. Transaction
[Mark Judge Level] exceeds the range of setting.
(Cause 1) The data has exceeded the allowable range.
(Remedy 1) Set correct parameters.
1807029 Recog. Transaction
Image around ducial mark was unstable.
1807030
Recog. Transaction
Error of mark gure similitude was extensive.
1807031 Recog. Transaction
Error of mark similitude or mark size was extensive.
1807032 Recog. Transaction
Specied mark was not found in window of recog.monitor.
(Cause 1) The ducial marks do not conform to the coordinates X and Y of the ducial
marks or the recognition mark data in the pattern program.
(Remedy 1) Follow the steps below to reset the machine to the normal condition. Refer to
"Error ID "1801032"" for details.
4OM-1505
2-53
2. Troubleshooting on Each Section : Chap.2
0906-001
T4B50
Error ID Error Name, Description, Cause, and Remedy
1807038 Recog. Transaction
Unavailable ducial mark polality was set.
1807040 Recog. Transaction
Unavailable ducial mark area was set.
1807043 Recog. Transaction
Recognition system error.
1807056 Recog. Transaction
Recog. transaction time over.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Shut down the power of the machine once and power up the machine again.
After that, restart the operation. When the same error still occurs, contact our
service personnel for details.
4OM-1505
2-54
2. Troubleshooting on Each Section : Chap.2
(19 Stencil Recognition)
T4B51
Error ID Error Name, Description, Cause, and Remedy
1901000 Stencil Recog. #1
1901001 Stencil Recog. #1
[Camera ID] exceeds the range of setting.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and restart the operation. If the machine is not reset to its
normal condition, shut down the power of the machine once and power up
the machine again. After that, restart the operation. When the same error still
occurs, contact our service personnel for details.
1901003 Stencil Recog. #1
[Camera Gain] exceeds the range of setting.
1901004
Stencil Recog. #1
[Camera Level] exceeds the range of setting.
1901011 Stencil Recog. #1
[Mark Size D1] exceeds the range of setting.
1901012 Stencil Recog. #1
[Mark Size D2] exceeds the range of setting.
1901014 Stencil Recog. #1
[Mark Judge Level] exceeds the range of setting.
(Cause 1) The data has exceeded the allowable range.
(Remedy 1) Set correct parameters.