4OM-1505-004_w.pdf - 第171页

4OM-1505 2-56 2. T roubleshooting on Each Section : Chap.2 0906-001 T4B53 Error ID Error Name, Description, Cause, and Remedy 1901038 Stencil Recog. #1 Unavailable ducial mark polality was set. 1901040 Stencil Recog. #1…

100%1 / 181
4OM-1505
2-55
2. Troubleshooting on Each Section : Chap.2
0906-001
T4B52
Error ID Error Name, Description, Cause, and Remedy
1901029 Stencil Recog. #1
Image around ducial mark was unstable.
1901030 Stencil Recog. #1
Error of mark gure similitude was extensive.
1901031 Stencil Recog. #1
Error of mark similitude or mark size was extensive.
1901032 Stencil Recog. #1
Specied mark was not found in window of recog.monitor.
(Cause 1) The ducial marks do not conform to the coordinates X and Y of the ducial
marks or the recognition mark data in the pattern program.
(Remedy 1) Follow the steps below to reset the machine to the normal condition.
(1) When the [RETURN] button is pressed, the following window opens.
(2) When the actual ducial mark is out of the recognition area, move the
camera such that the mark can enter the recognition area. Select the
[Manual Alignment [ST
ART]] button and press one of the arrow buttons
in the "DIRECTION" and one of the "SPEED" buttons. While the [START]
button is being pressed, the camera keeps on moving.
(3) Select the [Retry Recog. [START]] button and press the [START] button.
When the recognition is completed successfully, this window automatically
closes.
(4) When the recognition still failed after the re-recognition operation, move
the camera such that the actual ducial mark can stay at the ducial mark
template (located at the center of the cross hair).
Note
Be sure to adjust the position of the ducial mark as accurately
as possible because the printing accuracy is affected by this
adjustment.
(5) Select the [Man. Align. nished [START]] button and press the [START]
button. The original window resumes.
Note
If the [STOP] button is pressed while the "Manual Alignment"
window is active, the processing is interrupted and the original
window resumes.
F4B6
4OM-1505
2-56
2. Troubleshooting on Each Section : Chap.2
0906-001
T4B53
Error ID Error Name, Description, Cause, and Remedy
1901038 Stencil Recog. #1
Unavailable ducial mark polality was set.
1901040 Stencil Recog. #1
Unavailable ducial mark area was set.
1901043 Stencil Recog. #1
Recognition system error.
1901056 Stencil Recog. #1
Recog. transaction time over.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Shut down the power of the machine once and power up the machine again.
After that, restart the operation. When the same error still occurs, contact our
service personnel for details.
1902000 Stencil Recog. #2
1902001 Stencil Recog. #2
[Camera ID] exceeds the range of setting.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1)
Zero all axes and restart the operation. If the machine is not reset to its
normal condition, shut down the power of the machine once and power up
the machine again. After that, restart the operation. When the same error still
occurs, contact our service personnel for details.
1902003 Stencil Recog. #2
[Camera Gain] exceeds the range of setting.
1902004
Stencil Recog. #2
[Camera Level] exceeds the range of setting.
1902011 Stencil Recog. #2
[Mark Size D1] exceeds the range of setting.
1902012 Stencil Recog. #2
[Mark Size D2] exceeds the range of setting.
1902014 Stencil Recog. #2
[Mark Judge Level] exceeds the range of setting.
(Cause 1) The data has exceeded the allowable range.
(Remedy 1) Set correct parameters.
1902029 Stencil Recog. #2
Image around ducial mark was unstable.
1902030 Stencil Recog. #2
Error of mark gure similitude was extensive.
1902031 Stencil Recog. #2
Error of mark similitude or mark size was extensive.
1902032
Stencil Recog. #2
Specied mark was not found in window of recog.monitor.
(Cause 1) The ducial marks do not conform to the coordinates X and Y of the ducial
marks or the recognition mark data in the pattern program.
(Remedy 1) Follow the steps below to reset the machine to the normal condition. Refer to
"Error ID "1901032"" for details.
4OM-1505
2-57
2. Troubleshooting on Each Section : Chap.2
0906-001
T4B54
Error ID Error Name, Description, Cause, and Remedy
1902038 Stencil Recog. #2
Unavailable ducial mark polality was set.
1902040 Stencil Recog. #2
Unavailable ducial mark area was set.
1902043 Stencil Recog. #2
Recognition system error.
1902056 Stencil Recog. #2
Recog. transaction time over.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Shut down the power of the machine once and power up the machine again.
After that, restart the operation. When the same error still occurs, contact our
service personnel for details.
1904000 Stencil Recog. T
est
1904001 Stencil Recog. Test
[Camera ID] exceeds the range of setting.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and restart the operation. If the machine is not reset to its
normal condition, shut down the power of the machine once and power up
the machine again. After that, restart the operation. When the same error still
occurs, contact our service personnel for details.
1904003 Stencil Recog.
Test
[Camera Gain] exceeds the range of setting.
1904004 Stencil Recog. Test
[Camera Level] exceeds the range of setting.
1904011 Stencil Recog. Test
[Mark Size D1] exceeds the range of setting.
1904012 Stencil Recog. Test
[Mark Size D2] exceeds the range of setting.
1904014 Stencil Recog. Test
[Mark Judge Level] exceeds the range of setting.
(Cause 1) The data has exceeded the allowable range.
(Remedy 1) Set correct parameters.
1904029 Stencil Recog. Test
Image around ducial mark was unstable.
1904030
Stencil Recog. Test
Error of mark gure similitude was extensive.
1904031 Stencil Recog. Test
Error of mark similitude or mark size was extensive.
1904032 Stencil Recog. Test
Specied mark was not found in window of recog.monitor.
(Cause 1) The ducial marks do not conform to the coordinates X and Y of the ducial
marks or the recognition mark data in the pattern program.
(Remedy 1) Follow the steps below to reset the machine to the normal condition. Refer to
"Error ID "1901032"" for details.