4OM-1505 2-57 2. T roubleshooting on Each Section : Chap.2 0906-001 T4B54 Error ID Error Name, Description, Cause, and Remedy 1902038 Stencil Recog. #2 Unavailable ducial mark polality was set. 1902040 Stencil Recog. #2…

4OM-1505
2-56
2. Troubleshooting on Each Section : Chap.2
0906-001
T4B53
Error ID Error Name, Description, Cause, and Remedy
1901038 Stencil Recog. #1
Unavailable ducial mark polality was set.
1901040 Stencil Recog. #1
Unavailable ducial mark area was set.
1901043 Stencil Recog. #1
Recognition system error.
1901056 Stencil Recog. #1
Recog. transaction time over.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Shut down the power of the machine once and power up the machine again.
After that, restart the operation. When the same error still occurs, contact our
service personnel for details.
1902000 Stencil Recog. #2
1902001 Stencil Recog. #2
[Camera ID] exceeds the range of setting.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1)
Zero all axes and restart the operation. If the machine is not reset to its
normal condition, shut down the power of the machine once and power up
the machine again. After that, restart the operation. When the same error still
occurs, contact our service personnel for details.
1902003 Stencil Recog. #2
[Camera Gain] exceeds the range of setting.
1902004
Stencil Recog. #2
[Camera Level] exceeds the range of setting.
1902011 Stencil Recog. #2
[Mark Size D1] exceeds the range of setting.
1902012 Stencil Recog. #2
[Mark Size D2] exceeds the range of setting.
1902014 Stencil Recog. #2
[Mark Judge Level] exceeds the range of setting.
(Cause 1) The data has exceeded the allowable range.
(Remedy 1) Set correct parameters.
1902029 Stencil Recog. #2
Image around ducial mark was unstable.
1902030 Stencil Recog. #2
Error of mark gure similitude was extensive.
1902031 Stencil Recog. #2
Error of mark similitude or mark size was extensive.
1902032
Stencil Recog. #2
Specied mark was not found in window of recog.monitor.
(Cause 1) The ducial marks do not conform to the coordinates X and Y of the ducial
marks or the recognition mark data in the pattern program.
(Remedy 1) Follow the steps below to reset the machine to the normal condition. Refer to
"Error ID "1901032"" for details.

4OM-1505
2-57
2. Troubleshooting on Each Section : Chap.2
0906-001
T4B54
Error ID Error Name, Description, Cause, and Remedy
1902038 Stencil Recog. #2
Unavailable ducial mark polality was set.
1902040 Stencil Recog. #2
Unavailable ducial mark area was set.
1902043 Stencil Recog. #2
Recognition system error.
1902056 Stencil Recog. #2
Recog. transaction time over.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Shut down the power of the machine once and power up the machine again.
After that, restart the operation. When the same error still occurs, contact our
service personnel for details.
1904000 Stencil Recog. T
est
1904001 Stencil Recog. Test
[Camera ID] exceeds the range of setting.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and restart the operation. If the machine is not reset to its
normal condition, shut down the power of the machine once and power up
the machine again. After that, restart the operation. When the same error still
occurs, contact our service personnel for details.
1904003 Stencil Recog.
Test
[Camera Gain] exceeds the range of setting.
1904004 Stencil Recog. Test
[Camera Level] exceeds the range of setting.
1904011 Stencil Recog. Test
[Mark Size D1] exceeds the range of setting.
1904012 Stencil Recog. Test
[Mark Size D2] exceeds the range of setting.
1904014 Stencil Recog. Test
[Mark Judge Level] exceeds the range of setting.
(Cause 1) The data has exceeded the allowable range.
(Remedy 1) Set correct parameters.
1904029 Stencil Recog. Test
Image around ducial mark was unstable.
1904030
Stencil Recog. Test
Error of mark gure similitude was extensive.
1904031 Stencil Recog. Test
Error of mark similitude or mark size was extensive.
1904032 Stencil Recog. Test
Specied mark was not found in window of recog.monitor.
(Cause 1) The ducial marks do not conform to the coordinates X and Y of the ducial
marks or the recognition mark data in the pattern program.
(Remedy 1) Follow the steps below to reset the machine to the normal condition. Refer to
"Error ID "1901032"" for details.

4OM-1505
2-58
2. Troubleshooting on Each Section : Chap.2
0906-001
T4B55
Error ID Error Name, Description, Cause, and Remedy
1904038 Stencil Recog. Test
Unavailable ducial mark polality was set.
1904040 Stencil Recog. Test
Unavailable ducial mark area was set.
1904043 Stencil Recog. Test
Recognition system error.
1904056 Stencil Recog. Test
Recog. transaction time over.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Shut down the power of the machine once and power up the machine again.
After that, restart the operation. When the same error still occurs, contact our
service personnel for details.
1906000 Stencil Recog. Camera
1906001 Stencil Recog. Camera
[Camera ID] exceeds the range of setting.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1)
Zero all axes and restart the operation. If the machine is not reset to its
normal condition, shut down the power of the machine once and power up
the machine again. After that, restart the operation. When the same error still
occurs, contact our service personnel for details.
1906003 Stencil Recog. Camera
[Camera Gain] exceeds the range of setting.
1906004
Stencil Recog. Camera
[Camera Level] exceeds the range of setting.
1906011 Stencil Recog. Camera
[Mark Size D1] exceeds the range of setting.
1906012 Stencil Recog. Camera
[Mark Size D2] exceeds the range of setting.
1906014 Stencil Recog. Camera
[Mark Judge Level] exceeds the range of setting.
(Cause 1) The data has exceeded the allowable range.
(Remedy 1) Set correct parameters.
1906029 Stencil Recog. Camera
Image around ducial mark was unstable.
1906030 Stencil Recog. Camera
Error of mark gure similitude was extensive.
1906031 Stencil Recog. Camera
Error of mark similitude or mark size was extensive.
1906032
Stencil Recog. Camera
Specied mark was not found in window of recog.monitor.
(Cause 1) The ducial marks do not conform to the coordinates X and Y of the ducial
marks or the recognition mark data in the pattern program.
(Remedy 1) Follow the steps below to reset the machine to the normal condition. Refer to
"Error ID "1901032"" for details.