4OM-1505 2-62 2. T roubleshooting on Each Section : Chap.2 0906-001 T4B59 Error ID Error Name, Description, Cause, and Remedy 21 13000 Illegal Operation V acuum cleaning can not use in vacuum plate chuck on. (Cause 1) Th…

4OM-1505
2-61
2. Troubleshooting on Each Section : Chap.2
(21 Operator’s Error)
T4B58
Error ID Error Name, Description, Cause, and Remedy
2102000 Illegal Operation
PCB was took on inp. conveyor.
(Cause 1) Although a manual operation cannot be implemented with a PCB on the input
conveyor, such an operation was performed with a PCB.
(Remedy 1) Remove the PCB on the input conveyor and restart the operation.
2103000 Illegal Operation
PCB removed from input conveyor.
(Cause 1) Although a manual operation cannot be implemented without a PCB on the
input conveyor, such an operation was performed without a PCB.
(Remedy 1)
Place a PCB on an area of the input conveyor where the sensor reacts.
2105000 Illegal Operation
Current program was not identied. Please select program data.
(Cause 1) The automatic or the manual operation was performed without any pattern
program specied as a current one.
(Remedy 1) Perform a program change operation.
2106000 Illegal Operation
PCB was took on table.
(Cause 1) Although a manual operation cannot be implemented with a PCB on the table,
such an operation was performed with a PCB.
(Remedy 1) Remove the PCB on the table and restart the operation. Click the table
section (illustrated) in the "AUTO OPN." window to remove the PCB from the
memory of the machine whenever necessary.
2107000 Illegal Operation
PCB removed from table.
(Cause 1) Although a manual operation cannot be implemented without a PCB on the
table, such an operation was performed without a PCB.
(Remedy 1) Place a PCB on the table and restart the operation. Click the table section
(illustrated) in the "AUT
O OPN." window to set the PCB in the memory of the
machine whenever necessary.
2108000 Illegal Operation
PCB was took on output conveyor
.
(Cause 1) Although a manual operation cannot be implemented with a PCB on the output
conveyor, such an operation was performed with a PCB.
(Remedy 1) Remove the PCB on the output conveyor and restart the operation.
2109000 Illegal Operation
PCB removed from output conveyor.
(Cause 1) Although a manual operation cannot be implemented with a PCB on the output
conveyor, such an operation was performed with a PCB.
(Remedy 1) Place a PCB on an area of the output conveyor where the sensor reacts.
0906-001

4OM-1505
2-62
2. Troubleshooting on Each Section : Chap.2
0906-001
T4B59
Error ID Error Name, Description, Cause, and Remedy
2113000 Illegal Operation
Vacuum cleaning can not use in vacuum plate chuck on.
(Cause 1) The operation timing is shifted from the normal one.
(Cause 2) A cleaning suction operation was performed during the vacuum cleaning (chuck
suction). (during the manual operation)
(Remedy 1) Shut down the power of the machine once and power up the machine again.
After that, restart the operation. When the same error still occurs, contact our
service personnel for details.
(Remedy 2) Cancel the cleaning suction operation through the manual operation and
restart the operation.
2114000 Illegal Operation
Vacuum plate can not use at vacuum cleaning on.
(Cause 1) The operation timing is shifted from the normal one.
(Cause 2) A
chuck suction operation was performed during the vacuum cleaning (chuck
suction). (during the manual operation)
(Remedy 1) Shut down the power of the machine once and power up the machine again.
After that, restart the operation. When the same error still occurs, contact our
service personnel for details.
(Remedy 2) Cancel the cleaning suction operation through the manual operation and
restart the operation.
2115000 Illegal Operation
Input conveyor width was out of specied range.
2116000
Illegal Operation
Table chute width was out of specied range.
2117000 Illegal Operation
Output conveyor width was out of specied range.
(Cause 1) The PCB dimension (Y) in the current pattern program differs extremely from
the input conveyor width.
(Remedy 1) Open the "COLLCTVE. SETUP" window and change the conveyor width.
2118000 Illegal Operation
Stencil recog. was not nished.
(Cause 1) An operation was performed to check the results of the stencil recognition
although no stencil recognition operation is performed yet.
(Remedy 1) Perform the stencil recognition.

4OM-1505
2-63
2. Troubleshooting on Each Section : Chap.2
0906-001
T4B60
Error ID Error Name, Description, Cause, and Remedy
2121000 Illegal Operation
Not printed PCB exist on the table.
(Cause 1) An unprinted PCB was discharged during the automatic operation after an error
was canceled.
(Remedy 1) Remove the unprinted PCB on the table and restart the operation. Click the
table section (illustrated) in the "AUTO OPN." window to remove the PCB
from the memory of the machine whenever necessary.
2122000 Illegal Operation
Stencil was not found.
(Cause 1) The stencil clamping cancel check sensor (B6F) is turned OFF
.
(Remedy 1) Ins
tall the stencil and restart the operation. When an error occurs even though
the stencil is installed, it is required to adjust the sensor position or replace
the sensor with a new one. Contact our service personnel for details.
2123000 Illegal Operation
Reference position was not identied.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Perform the teaching operation again from the beginning.
2124000 Illegal Operation
Stencil was on the holder.
(Cause 1) The stencil clamping cancel check sensor (B6F) is turned ON.
(Remedy 1)
Detach the stencil and restart the operation. When this error still occurs even
though the stencil is detached, it is required to adjust the sensor position or
replace the sensor with a new one. Contact our service personnel for details.