4OM-1505 1-29 3. Maintenance Spots : Chap.1 3.2.6 PCB Chuck Section Upper Surface of PCB T ransfer Belt Every Day Cleaning PCB Positioning Side and Upper Surface Every Day Cleaning Upper Surface Section of Backup T able …

100%1 / 181
4OM-1505
1-28
3. Maintenance Spots : Chap.1
R Conveyor
Upper Surface of PCB Transfer
Belt
Every Day Cleaning
Remove solder paste and dust
with a vacuum cleaner.
Linear Guide
Every Month Cleaning
Clean the stopper with an oiled rag.
Do not leave any waste
threads after cleaning.
Every 5 years Lubrication
Apply grease with a brush or a
spatula.
Linear Guide
Note
F4A17
0906-001
4OM-1505
1-29
3. Maintenance Spots : Chap.1
3.2.6 PCB Chuck Section
 
Upper Surface of PCB Transfer
Belt
Every Day Cleaning
PCB Positioning Side and
Upper Surface
Every Day Cleaning
Upper Surface Section of
Backup Table
Every Week Cleaning
Remove solder paste and dust
using a cloth soaked in industrial
alcohol. In the case that solder
paste can not be removed, scrape it
and clean it again using a cloth
soaked in industrial alcohol.
Remove solder paste and dust
using a cloth soaked in industrial
alcohol. In the case that solder
paste can not be removed, scrape it
and clean it again using a cloth
soaked in industrial alcohol.
Remove solder paste and dust
using a cloth soaked in industrial
alcohol. In the case that solder
paste can not be removed, scrape it
and clean it again using a cloth
soaked in industrial alcohol.
F4A18
0906-001
4OM-1505
1-30
3. Maintenance Spots : Chap.1
Every 6 Months Lubrication
Backup Table Vertical-Axis
Guide Bushing (Three)
Backup Table Vertical-Axis
Ball Screw (Four)
Every 6 Months Lubrication
Backup Table Vertical-Axis
Guide Bushing
Every Month Cleaning
Clean the stopper with an oiled rag.
Do not leave any waste
threads after cleaning.
Note
(1)
(2)
Move up the backup table
Z axis.
Apply grease with a brush or
a spatula.
(1)
(2)
Move up the backup table
Z axis.
Apply grease with a brush or
a spatula.
F4A19
Linear Guide for PCB Clamping
Every Month Cleaning
Detach the cover and clean
the stopper with an oiled rag.
Do not leave any waste
threads after cleaning.
Linear Guide for PCB Clamping
Every 5 years Lubrication
Detach the cover and apply grease
with a brush or a spatula.
Rear Side
Note
F4A20
0906-001