Chapter 2 Zero setting
2.1 Cooling Fan Check
1. When the machine has been turned ON and the OS
has booted up check that the cooling fans are
operating properly and rotating in the correct
direction.
2. There is a servo amplifier rack in the electric box at
the right hand corner of the machine rear. On top,
there are two cooling fans. Check that they are
operating properly and rotating in the correct
direction, so that the air flows outwards.
2.2 Checking the Standard Proper
1. Check that the fixed values entered in the machine proper data match those in the
standard proper list.
Note: set the proper data item “TRAY DETECTION MOTION to 0 until the MTU is
adjusted in chapter 5. After the MTU has been adjusted, set the proper data to 1.
2.3 Checking the Digital Amplifier Parameters
Equipment: Digital Operator (JUSP-0P02A)
1. Press the M/C emergency stop so that the 200V power supply to the servos is cut.
2. Connect the digital operator to the relevant servo amplifier, (“bb displays at the screen).
3. Press [DSPL/SET] to select the channel mode (Pn000).
4. Specify the number of the channel to be checked, then press [DATA/ENTER] to display.
5. Ensure that the values match those listed in the machine servo amp parameter table.
6. When you have completed checking the parameters, return to the”bb” screen.
7. When the setting is completed, Re-boot the machine.
Example: [-bb] – [DSPL/SET] – [Pn-00] – [DATA/ENTER] – [Pn.001](setting)
-
¬