FK-9F98-29 XP Series Training Text for Service Engineers
Edition 5.0 XP241 – Chapter 8 Options Page 6 of 10
Fuji Machine Mfg. Co., Ltd. Okazaki
SMT Equipment Quality Assurance Dept.
8 – 6 CS Section
Proper Setting
1. Select [Maintenance C] – [Proper Data Editor] – [Machine_Type] and set “_Coplanarity”
to “1”.
2. Select [Maintenance C] – [Proper Data Editor] – [Others] and temporarily set
“_CoplaCamShutterSpeed” to “3000”.
Camera position
1. Set the coplanarity camera nozzle jig in position 1 of the nozzle change station.
2. Select [Production] – [Nozzle Editor] and set the nozzle size for position 1. Note that any
size is okay as long as the setting is not “Empty”.
3. Select [Manual Operation] – [Nozzle Operation] – [1] – [Execute] – [START] and pick up
the coplanarity camera nozzle jig from the nozzle change station.
4. Select [Maintenance C] – [Proper Data Editor] – [Others] and set the following proper
data items:
X_CoplanarityPosX 645
Y_CoplanarityPosY Here input the “_PrismBack” value input in chapter 6.6
Z_CoplanarityPosZ 43.7
5. Select [Maintenance A] – [Jog] and bring the X and Y axes to the positions input in step
4.
6. Once the positions of the X and Y-axes have been set, bring the Z-axis to 43.7mm.
7. Select the coplanarity camera and display the cross hairs on the screen.
8. The coplanarity camera jig should be visible. Temporarily set the focus of the coplanarity
camera by turning the focus ring on the end of the lens.
9. Adjust the position of the camera bracket so that the vertical cross hair is in the center of
the hole in the coplanarity camera nozzle jig. Please see the picture below:
5 memory scales
from the horizontal
cross hair
Vertical cross hair is
in the center of the
nozzle jig
FK-9F98-29 XP Series Training Text for Service Engineers
Edition 5.0 XP241 – Chapter 8 Options Page 7 of 10
Fuji Machine Mfg. Co., Ltd. Okazaki
SMT Equipment Quality Assurance Dept.
8 – 7 CS Section
10. Adjust the coplanarity camera tilt using the tilt adjusting bolt on the camera bracket.
11. The position of the camera should be adjusted so that the bottom edge of the jig is
aligned five memory scales above the horizontal cross hair. Please see the picture
below:
12. Once the camera position has been set lock all the bolts and confirm that the position
does not change.
Camera focus and brightness
1. Adjust the camera focus so that the corner edges of the coplanarity camera nozzle jig are
as clear and sharp as possible. Adjust the focus by turning the focus ring on the end of
the camera lens. Once the focus has been set lock the focus ring set bolt.
2. After setting the focus it is necessary to set the camera brightness. Touch the white
background on the monitor to get a brightness reading as shown below:
3. The brightness value should be 210 +/- 10. If not it is necessary to adjust the
“_CoplaCamShutterSpeed” value in proper data, this has already been set to 3000 by
default. Select [Maintenance C] – [Proper Data Editor] – [Others] –
[CoplaCamShutterSpeed] and adjust the value. Lowering the value will decrease the
coplanarity camera brightness, and raising the value will increase the brightness.
4. Continue editing the value until the brightness reading is 210 +/-10.
5 memory scales
from the horizontal
cross hair
Vertical cross hair is
in the center of the
nozzle jig
Touch anywhere in the
white background to
display a brightness
reading
FK-9F98-29 XP Series Training Text for Service Engineers
Edition 5.0 XP241 – Chapter 8 Options Page 8 of 10
Fuji Machine Mfg. Co., Ltd. Okazaki
SMT Equipment Quality Assurance Dept.
8 – 8 CS Section
Resolution measurement
1. Select [Maintenance A] – [I/O Check] and turn (Y01C CoplanarityLed) ON.
2. Select [Program] – [Template Editor].
3. Right click on the screen with a mouse and select [Utility] – [Scale Setting] to open the
“Camera Unit Ctrl” dialogue.
4. Click on the “scale setting” button to open up the scale setting screen as shown in the
picture below:
5. In the “Scale” dialogue input “20mm” in the “X_size” box.
6. Use the mouse to drag the two vertical caliper lines so that they are aligned with the left
and right edge of the coplanarity camera jig as shown in the picture below. There is no
need to align the horizontal caliper lines.
7. Once the two vertical caliper lines have been aligned with the jig and “20mm” input in
the “X_size” box, click on OK to return to the “Camera Unit Ctrl” dialogue.
8. Here the X-unit resolution figure should have been saved in the dialogue.
9. Now it is necessary to copy over the X_unit resolution figure to the Y_unit. To do this,
20mm
Scale
Setting