xp141-241-341-5.0E - 第44页
FK-9F98- 29 XP Series Training Text for Service Engineers Edition 5.0 XP141 – Chapter 5 Peripheral Adjustments Page 6 of 16 Fuji Machine Mfg. Co., Ltd. Okazaki SMT Equipment Quality Assurance Dept. 5 – 6 CS Section Adjus…

FK-9F98-29 XP Series Training Text for Service Engineers
Edition 5.0 XP141 – Chapter 5 Peripheral Adjustments Page 5 of 16
Fuji Machine Mfg. Co., Ltd. Okazaki
SMT Equipment Quality Assurance Dept.
5 – 5 CS Section
Configuration DA (Double detection sensor Xno.93 or earlier)
Feeder tape leaf detection sensor: Yamatake fiber type
Feeder set check sensor: Yamatake LED type
Configuration DB (Double detection sensor Xno.94 or later)
Feeder tape leaf detection sensor: Yamatake fiber type
Feeder set check sensor: Schmersl LED type

FK-9F98-29 XP Series Training Text for Service Engineers
Edition 5.0 XP141 – Chapter 5 Peripheral Adjustments Page 6 of 16
Fuji Machine Mfg. Co., Ltd. Okazaki
SMT Equipment Quality Assurance Dept.
5 – 6 CS Section
Adjustment for configuration A
1. Clamp the MFU and load two feeder sensor adjustment jigs (Z9631ADEPJ1000) at slots
D47 and D49 at side 1.
2. Fix the front sliding attachments at their backward limit (in the direction away from the
machine interior) and insert a 1.8mm diameter wire jig between the holes in the
attachments. Adjust the tape leaf check sensor position so that the point where the
sensor beam is emitted is aligned with the center of the wire jig.
3. Fix the rear sliding attachments at their forward limit (in the direction towards the machine
interior) and insert a 1.8mm diameter wire jig between the holes in the attachments.
Adjust the feeder set check sensor position so that the point where the sensor beam is
emitted is aligned with the center of the wire jig.
4. Check the tilt of both sensors.
5. Move the feeder sensor jigs to D2 and D4 and repeat steps 2 to 4 for the sensors at the
left side of the MFU.
6. Finally check the operation of both sets of sensors by I/O.
Feeder set check sensor FH1000_1: [X017] Side 1 XY Axis Inter
Feeder tape leaf detection sensor FH1000_2: [X02C] Side1 FdeDetect
Z9631ADEPJ1000
D49D47
Tape leaf check sensor
D47
D49
Feeder set check sensor
Sensor
BKT
BKT

FK-9F98-29 XP Series Training Text for Service Engineers
Edition 5.0 XP141 – Chapter 5 Peripheral Adjustments Page 7 of 16
Fuji Machine Mfg. Co., Ltd. Okazaki
SMT Equipment Quality Assurance Dept.
5 – 7 CS Section
Adjustment for configuration B
1. Clamp the MFU and load two EC type feeder sensor adjustment jigs (Z9631ADEPJ8040)
at slots D47 and D49.
2. Fix the front sliding attachments at their backward limit (in the direction away from the
machine interior) and insert a 1.8mm diameter wire jig between the holes in the
attachments. Adjust the tape leaf check sensor position so that the point where the
sensor beam is emitted is aligned with the center of the wire jig.
3. Fix the sliding attachments for the Schmersl sensor at their forward limit (in the direction
towards the machine interior) and insert a 1.8mm diameter wire jig between the holes in
the attachments. Adjust the feeder set check sensor position so that the point where the
sensor beam is emitted is aligned with the center of the wire jig.
4. Check the tilt of both sensors:
5. Move the feeder sensor jigs to D2 and D4 and repeat steps 2 to 4 for the sensors at the
left side of the MFU.
6. Finally check the operation of both sets of sensors by I/O.
Feeder set check sensor FH1000_1: [X017] Side 1 XY Axis Inter
Feeder tape leaf detection sensor FH1000_2: [X02C] Side1 FdeDetect
D49D47
Tape leaf check sensor
D49
D47
Z9631ADEPJ8040
Sensor
BKT