FK-9F98- 29 XP Series Training Text for Service Engineers Edition 5.0 XP141 – Chapter 5 Peripheral Adjustments Page 9 of 16 Fuji Machine Mfg. Co., Ltd. Okazaki SMT Equipment Quality Assurance Dept. 5 – 9 CS Section Adjus…

100%1 / 234
FK-9F98-29 XP Series Training Text for Service Engineers
Edition 5.0 XP141 – Chapter 5 Peripheral Adjustments Page 8 of 16
Fuji Machine Mfg. Co., Ltd. Okazaki
SMT Equipment Quality Assurance Dept.
5 – 8 CS Section
Adjustment for configuration C
1. Clamp the MFU and load two EC type feeder sensor adjustment jigs
(Z9631ADEPJ8040) at slots D47 and D49 at side 1.
2. Fix the front sliding attachments at their backward limit (in the direction away from the
machine interior) and insert a 1.8mm diameter wire jig between the holes in the
attachments. Adjust the tape leaf check sensor position so that the point where the
sensor beam is emitted is aligned with the center of the wire jig.
3. Move the two feeder sensor adjustment jigs to slots D2 and D4 and then repeat step 2
for the tape leaf check sensor on the left side of the MFU.
4. Load two EC type feeder sensor adjustment jigs (with AA-mode feeder set check sensor
position adjustment jig plates attached) at D2 and D49 at side 1. Adjust the position of
the feeder set check sensor transmitter and receiver so that the light beam goes through
the holes in the attachment plates. Use I/O X017 to monitor the signal.
5. Check the tilt of the sensors and confirm they are not triggered by the XY robot.
6. Finally check the operation of both sets of sensor by I/O.
Feeder set check sensor FH1000_1: [X017] Side 1 XY Axis Inter
Feeder tape leaf detection sensor FH1000_2: [X02C] Side1 FdeDetect
AA mode feeder set check
sensor position adjustment jig
plate
D49D47
Tape leaf check sensor
Hole in
attachment
plate
Z9631ADEPJ8040
Front sliding
attachment
FK-9F98-29 XP Series Training Text for Service Engineers
Edition 5.0 XP141 – Chapter 5 Peripheral Adjustments Page 9 of 16
Fuji Machine Mfg. Co., Ltd. Okazaki
SMT Equipment Quality Assurance Dept.
5 – 9 CS Section
Adjustment for configurations DA and DB (double detection type)
For details of how to adjust the feeder set check sensors for configurations DA and DB, refer
to the adjustment procedures for configurations A and B. The adjustment procedure
described below is for the “double detection type” tape leaf sensor only.
Initial setting
1. Fix the attachment to the fiber sensor using Loctite 222 adhesive.
Amplifier frequency setting
1. Set the L-ON/D-ON changeover switch to L_ON.
2. Press the dial switch once (the RUN light in the Mode Display flashes and “AA” is
displayed on the digital display).
3. Turn the dial switch until SET flashes on the “Mode Display”.
LO DO
RUN
SET
TMR
ADJ
Digital Display
Operation Light
L-ON/D-ON Changeover Switch
Dial Switch
Mode Display
Mode Lights
Double detection type tape leaf sensors
Attachment
Fiber sensor
Apply Loctite 222 here
FK-9F98-29 XP Series Training Text for Service Engineers
Edition 5.0 XP141 – Chapter 5 Peripheral Adjustments Page 10 of 16
Fuji Machine Mfg. Co., Ltd. Okazaki
SMT Equipment Quality Assurance Dept.
5 – 10 CS Section
4. Press and hold the dial switch for 3 seconds (SET stops flashing and the Mode Lights
come ON).
5. Turn the dial switch until “– –“ is displayed on the digital display.
6. Press and hold the dial switch for 8 seconds.
7. Turn the dial to select F1 or F2 depending on which of the two amplifiers are being
adjusted (refer to the photo of the amplifiers below).
8. Press the dial switch once so that SET in the Mode Display flashes.
9. Turn the dial until RUN in the mode display flashes.
10. Press the dial switch once (RUN stops flashing and a number 1~100 displays in the
digital display).
11. Repeat the procedure for the other amp.
HP mode and sensor position setting
1. Press the dial switch once (the RUN light in the Mode Display flashes and “AA” is
displayed on the digital display).
2. Turn the dial switch until SET flashes on the “Mode Display”.
3. Press and hold the dial switch for 3 seconds (SET stops flashing and the Mode Lights
come ON).
4. Turn the dial switch until “HP” is displayed on the digital display.
5. Press the dial switch once (SET in the mode display flashes).
6. Press the dial switch once so that “2P” flashes on the digital display.
7. Turn the dial until a number 1~100 displays on the digital display.
8. Clamp the MFU and set sensor adjustment jigs (Z9731ADEPJ8070) in slots D47 and
D49.
F1F2