MIL-STD-883F
METHOD 1007
1 May 1968
1
METHOD 1007
AGREE LIFE
1. PURPOSE
. The purpose of this test is to determine a representative failure rate for microelectronic devices or to
demonstrate quality or reliability of devices subjected to the specified conditions where test conditions include a combination
of temperature cycling, on-off electrical stressing and vibration to simulate as closely as possible actual system applications
and environments.
2. APPARATUS
. The apparatus required shall be described in method 1005 of this standard except that the temperature
chambers shall be capable of following the specified test profile of figures 1 or 2 of MIL-STD-781 and suitable equipment
shall be provided to satisfy the requirements for vibration as specified.
3. PROCEDURE
. This test shall be conducted in accordance with all the requirements of method 1005 of this standard
with the exceptions that temperature shall be cycled, periodic vibration shall be applied, and electrical stresses shall be
applied in on-off cycles where and as required in the specified test level of MIL-STD-781. Only test levels E, F, G, H and J
of MIL-STD-781 shall be considered acceptable as test conditions. Selection of the temperature range should take into
account the temperature rise associated with the devices under test.
Test conditions
for method 1007
Test level
in accordance with
MIL-STD-781
Temperature range
°C
A E -54 to +55
B F -54 to +71
C G -54 to +95
D H -65 to +71
E J -54 to +125
F Test level F with
modified low
temperature
0 to +70
4. SUMMARY
. In addition to the requirements of method 1005 of this standard, the following details shall be specified in
the applicable acquisition document:
a. Test condition (see 3).
b. Test profile, specify figure 1 or 2 MIL-STD-781 and specify on-time and transfer-times, as applicable.
c. Total on-time
MIL-STD-883F
METHOD 1007
1 May 1968
2
This page intentionally left blank
.
MIL-STD-883F
METHOD 1008.2
25 August 1993
1
METHOD 1008.2
STABILIZATION BAKE
1. PURPOSE
. The purpose of this test is to determine the effect on microelectronic devices of storage at elevated
temperatures without electrical stress applied. This method may also be used in a screening sequence or as a
preconditioning treatment prior to the conduct of other tests. This test shall not be used to determine device failure rates for
other than storage conditions. It may be desirable to make end point and, where applicable, intermediate measurements on
a serialized device basis or on the basis of a histogram distribution by total sample in order to increase the sensitivity of the
test to parameter degradation or the progression of specific failure mechanisms with time and temperature.
2. APPARATUS
. The apparatus required for this test shall consist of a controlled temperature chamber capable of
maintaining the specified temperature and suitable electrical equipment to make the specified end point measurements.
3. PROCEDURE
. The device shall be stored at the specified ambient conditions for the specified time. The time at high
temperature shall be sufficient to allow the total mass of each device under test to reach the specified temperature before
the specified time duration begins. Within the time interval of 24 hours before (0 hours before test durations less than 250
hours) to 72 hours after the specified duration of the test, the device shall be removed from the specified ambient test
condition and allowed to reach standard test conditions. When specified, end-point measurements shall be completed
within 96 hours after removal of device from the specified ambient test condition. When specified (or at the manufacturer's
discretion, if not specified) intermediate measurements shall be made at intermediate points.
3.1 Test condition
. The ambient test temperature shall be indicated by specifying a test condition letter from the following
table. The specified test temperature is the minimum actual ambient temperature to which all devices in the working area of
the chamber are exposed. This shall be assured by making whatever adjustments are necessary in the chamber profile,
loading, location of control or monitoring instruments, and the flow of air or other chamber atmosphere. Therefore,
calibration, shall be accomplished on the chamber in a fully, loaded, unpowered configuration, and the indicator sensor
located at, or adjusted to reflect, the coldest point in the working area. Unless otherwise specified, test condition C
minimum, with a minimum time duration and temperature as specified in table I, shall apply. Unless otherwise specified, the
test duration for all other test conditions shall be 24 hours minimum.
Test condition
Temperature (minimum)
A 75°C
B 125°C
C See table I
D 200°C
E 250°C
F 300°C
G 350°C
H 400°C