ts9800-user-guide-7511-0360_A - 第4页

4 1. SAFETY 1.1 Intended Use OK International cannot be responsible for injuries or damages resultin g from u nintended applications o f its equipment. Unintended u ses m ay result from taking the following actions: • Ma…

100%1 / 52
3
9.4 Symbol Definitions ……………………………………………
9.5 Operation
9.5.1 Login ……………………………………………
9.5.2 Disable password protection.…………………..
9.5.3 Enable password protection ……………………
9.5.4 Resetting master password …………………………….
9.5.5 Setup dispensing parameters ……………………………
9.5.6 Calling up dispense parameters……………………….
9.5.7 Reset cycle counter ……………………………
9.5.8 To run Dot or Line mode ……………….…………..
9.5.9 Service Mode ………………………………..
9.5.10 Wi-Fi (Not available) ………………..……..
9.5.11 IOT (Remote Communication) ………………..……..
9.5.12 Software Update ……………………………….
10. SPARE PARTS AND SCHEMATICS
10.1 Tappets & Nozzle Inserts ……………………………………..
10.2 Tools …………………………………………….……………
10.3 Jet Valves parts list …………………………….…………….
10.3 DB-15 Connector …….……………………………………….
10.3 DB-9 Connector……………………………………………….
11. TROUBLE SHOOTING
11.1 General problems…………..………………………………………….
11.2 General functions……………..……………………………
11.3 General parameters ……………………………………………..
12. WARRANTY AND RETURN
12.1 Warranty……………………………………………………….
12.2 Return…………………………………………………….…….
34
35
35-36
36
36-37
37-39
39
39-40
40
41
41
41-43
43
44
44
45
46
46
46
47
46
47
48
49
50
51
4
1. SAFETY
1.1 Intended Use
OK International cannot be responsible for injuries or damages resulting
from unintended applications of its equipment. Unintended uses may result
from taking the following actions:
Making changes to equipment that has not been recommended in the
User Guide
Using incompatible or damaged replacement parts
Using unapproved accessories or auxiliary equipment
1.2 Safety Precautions
Do not operate this unit in excess of maximum ratings/settings
Always wear appropriate personal protective clothing or apparel
This equipment is for indoor use only
1.3 Specified Normal Operation
The TS9800 System can be used for dispensing fluids with a wide range
of fluid viscosity.
Additional heating may only be carried out with a heating system from
Techcon Systems
The usage of the TS9800 System can be carried out under laboratorial or
production environment.
Provided the highest frequencies (up to 1500 Hz; average frequency
should not exceed 800 Hz) and parameter settings must be followed.
The usage of media which affects the functioning of the TS9800 System
must be avoided.
1.4 Technical Details
The usage of the TS9800 System is only allowed inside and up to 2000
meters above sea level.
Relative humidity: maximum 80% at 31 °C, decreasing linear until 50%
at 50 °C.
Fluctuation of the line voltage is not allowed over ± 10% of the nominal
voltage.
Transient over voltage according to IEC 60364-4-443 will be tolerated:
degree of pollution 2 is allowed.
The employed power cords must be accompanied by an earthing
equipment conductor. The used power sockets must be within safety
regulations. When using cable, which are not supplied by OK
International, the warranty of the TS9800 System will only range till the
operator interface.
During installation and operation please pay attention to supply enough
air circulation: minimum distance above and below the system (valve
and control unit) are 1.5 cm. OK International advises a separate housing
which is in alignment of fire prevention covering EN 61010-1.
5
When using the TS9800 Jet Valve with heater, please note that the
tangible surfaces can be hot which can lead to severe burns.
The offered safety by the apparatus can be affected by using parts/units
not advised by OK International. The same can be considered for the
usage of dangerous substances or the operation in an explosive
environment, for which the TS9800 System is not designed for.
1.5 Warning Notices
Never use the valve without nozzle insert or without fluid.
Never disconnect the cables during the dispensing process.
Avoid fast turning on and off to the control unit.
Avoid long stand-by durations while the system is switched on.
The TS9800 System is constructed modularly. If a defect occurs, the
effected module should not be interchanged with other parts. The whole
system needs to be sent back to Techcon Systems for repair. The cables
can stay with the customer but need to be checked. Information of how
to check the performance is available from Techcon Systems.
Avoid hard placing of the valve on the working surfaces during
mounting and dismounting.
Store the valve on a flat surface during the cleaning procedures. Do not
shake or bang the valve on any hard surface.
For cleaning the valve, use a damp (isopropanol) cloth and make sure
that no fluid leaks into the valve (e. g. via connectors).
Never connect the TS9800 Jet Valve to a control unit different than the
TS980 (connecting it to another control system will damage the valve).
Check whether all fluid connections are attached and sealed.
Make sure that all fluid contacting parts are stable against the fluid.
Make sure that all electronic connections are connected and interlocked.
Make sure the supply pressure does not exceed the admissible range.
Make sure the maximum possible system pressure ranges between the
valve limit and the connection supplies limit - in no case above it.
Check before the use of a heating device that the fluid does not tend to
unwanted reactions at elevated temperatures.
When using a heating device make sure that the set temperature does not
exceed recommended temperature of the material (consult with the
material manufacture).
When using a heating device please pay attention to the syringe/cartridge
feeding pressure.
The heating of the TS9800 System cannot exceed 90°C.
The TS9800 Jet Valve works with the normally-open concept.
Therefore, without supply voltage, the valve will open, and the fluid may
leak. To avoid leakage, disconnect air supply to the fluid syringe before
shutting down the control unit.