Nordson_EFD_OptiSure_Operating_Manual - 第19页
OptiSure Automated Optical Inspection 19 www.nordsonefd.com info@nordsonefd.com +1-401-431-7000 Sales and service of Nordson EFD dispensing systems are available worldwide. # Click Step Reference Image 4 > > > &…

OptiSure Automated Optical Inspection
18 www.nordsonefd.com info@nordsonefd.com +1-401-431-7000 Sales and service of Nordson EFD dispensing systems are available worldwide.
Gravity Point Example
Gravity Point is an OptiSureAOI feature that allows you to create two Fiducial Marks in the center of a line, one at
the beginning of the line and the other at the end of the line. Then, if a subsequent dispense must be made on a line
that is thicker or thinner, the system can dispense through the center of that line using the Fiducial Mark offsets.
PREREQUISITES
To learn how to use this feature, draw two lines of different thicknesses on a sheet of white paper and use it as a
workpiece template.
Using the Arrow Types (continued)
To Create a Gravity Point Mark Image
# Click Step Reference Image
1
>
• Click CAMERA > SETUP and enter a
lower score for SENSE (1 is used in
this example).
NOTE: You may need to adjust this
value based on the results as you
work through this procedure.
2
>
>
1.
2.
>
• Jog the camera to a location near
the beginning of the thicker line.
• Click SET MARK, then click and
drag the red box (item 1) over the
line.
• Double-click the crosshairs in the
center of the red box (item 2) and
then enter the desired values for
Width and Height (20 and 60 in this
example).
• Click OK to save the values.
3
>
• Click a socket in the Mark Library to
save the mark, then click TEMPLATE
when the Template Match window
appears.
The system saves the image in the
Mark Library.
Continued on next page

OptiSure Automated Optical Inspection
19www.nordsonefd.com info@nordsonefd.com +1-401-431-7000 Sales and service of Nordson EFD dispensing systems are available worldwide.
# Click Step Reference Image
4
> >
>
>
• Click RANGE to set where the
system searches for the mark.
• Double-click on the crosshairs in the
center of the mark and enter Width
and Height values (20 and 480 in this
example).
NOTE: The Width value must be
the same as the Width specified in
step2 on page18.
• Click OK.
• Click RANGE again to save.
5
>
• Click the ARROW icon.
• In the Primary View screen, right-
click and select ADD NEW ARROW.
The system adds an arrow to the
screen.
6
3.
4.
5.
• Repeat step 5 to add another
arrow, and then use the mouse to
manipulate the arrows so they form
an array, as shown.
- To move the entire arrow, click
and drag the middle box (item4).
- To elongate or shorten the arrow,
click and drag the arrow (item5)
or the end box (item3).
7 • Right-click on the middle box of an
arrow and then select PARAMETER.
The AOI Arrow window opens.
Continued on next page
Gravity Point Example (continued)
To Create a Gravity Point Mark Image (continued)
Using the Arrow Types (continued)

OptiSure Automated Optical Inspection
20 www.nordsonefd.com info@nordsonefd.com +1-401-431-7000 Sales and service of Nordson EFD dispensing systems are available worldwide.
# Click Step Reference Image
8
• Select the ALL checkbox (because
two arrows are used).
• For Type, select GRAVITY POINT.
9 • Adjust THRESHOLD until the
two small red circles (item 6) are
positioned on the top and bottom
edges of the line.
6.
6.
10 • Select LIGHT TO DARK.
• Adjust PIXEL AVG to make the mark
image easier for the system to find.
NOTE: Select CENTER if you want
to center the image based on the
image in the mark library.
• Close the dialog box to save the
settings.
The saved mark image now contains
additional data that will allow the
system to accurately find it upon
reaching its corresponding Fiducial
Mark command in a program.
• Continue to “To Use a Gravity
Point Mark Image in a Program” on
page21 to use the Gravity Point
mark image.
Using the Arrow Types (continued)
Gravity Point Example (continued)
To Create a Gravity Point Mark Image (continued)