00197902-03_UM_X-Serie-S_EN - 第115页
User manual SIPLACE X-Series 3 Technical data and assemblies From software version 710.0 Edition 12/2016 3.1 Performance data 115 3.1.6 SIPLACE X3 S machine performa nce 3 Placement head types SIPLACE SpeedStar (C&P2…

3 Technical data and assemblies User manual SIPLACE X-Series
3.1 Performance data From software version 710.0 Edition 12/2016
114
3.1.4 Machine performance SIPLACE X4 S micron
3
3.1.5 Machine performance SIPLACE X4i S micron
3
Placement head types SIPLACE SpeedStar (C&P20 M)
SIPLACE MultiStar (CPP)
SIPLACE X4 S micron
Placement performance
For a definition of placement performance values, see the note on page 111.
Placement area 1 Placement area 2 IPC value Benchmark
value
Theoretical
value
C&P20 M / C&P20 M C&P20 M / C&P20 M 82,000
*a
90,000
a
124,000
a
C&P20 M / C&P20 M C&P20 M / C&P20 M 62,000
*b
70,000
b
95,000
b
C&P20 M / C&P20 M CPP_L/CPP_L 86,500 102,000 145,000
C&P20 M / C&P20 M CPP_H / CPP_H 86,000 95,000 134,400
*)a Without "High Precision" option
*)b With "High Precision" option
Placement head types SIPLACE SpeedStar (C&P20 M)
SIPLACE MultiStar (CPP)
SIPLACE X4i S micron
Placement performance
For a definition of placement performance values, see the note on page 111.
Placement area 1 Placement area 2 IPC value Benchmark
value
Theoretical
value
C&P20 M / C&P20 M C&P20 M / C&P20 M 102,000 120,000 135,500
C&P20 M / C&P20 M CPP_L/CPP_L 91,500 103,500 123,750
C&P20 M / C&P20 M CPP_H / CPP_H 85,000 100,000 112,500
Important notes
When setting up a machine (S; F, HS, HF, X or D-Series) next to a SIPLACE X-Series, be aware that there is limited room between the two
machines. In these cases, use a suitable conveyor extension to create room of 0.5m for the operator between the two machines.
To achieve top placement performance, fit the first machine in a SIPLACE X-Series S line with a input conveyor extension and the last
machine in the line with an output conveyor extension.
CPP_H = Multistar CPP in high assembly position
CPP_L = Multistar CPP in low assembly position

User manual SIPLACE X-Series 3 Technical data and assemblies
From software version 710.0 Edition 12/2016 3.1 Performance data
115
3.1.6 SIPLACE X3 S machine performance
3
Placement head types SIPLACE SpeedStar (C&P20)
SIPLACE SpeedStar (C&P20 P)
SIPLACE MultiStar (CPP)
SIPLACE TwinStar (TH)
SIPLACE X3 S
Placement performance
For a definition of placement performance values, see the note on page 111.
Machine Placement area 1 Placement area 2 IPC value Benchmark
value
Theoretical
value
X3 S-A C&P20 / C&P20 C&P20 65,000 76,450 102,300
C&P20 / C&P20 CPP_L 62,200 73,150 99,000
C&P20 / C&P20 CPP_H 59,100 69,500 94,000
C&P20 P / C&P20 P C&P20 P 78,100 93,750 127,875
C&P20 P / C&P20 P CPP_L 73,200 86,150 117,500
C&P20 P / C&P20 P CPP_H 70,100 82,500 112,530
CPP_L/CPP_L CPP_L 57,500 67,650 92,400
CPP_H / CPP_H CPP_H 49,750 58,500 78,250
CPP_L/CPP_L CPP_H 54,000 63,500 85,000
X3 S-B C&P20 / C&P20 TH 46,750 55,000 75,350
C&P20 P / C&P20 P TH 57,000 67,500 92,070
CPP_L/CPP_L TH 41,650 49,000 68,750
CPP_H / CPP_H TH 37,400 44,000 60,200
X3 S-C CPP_H/TH TH 25,500 29,100 41,250
X3 S-D TH / TH TH 11,900 14,000 21,450
Important notes
When setting up a machine (S; F, HS, HF, X or D-Series) next to a SIPLACE X-Series, be aware that there is limited room between the two
machines. In these cases, use a suitable conveyor extension to create room of 0.5m for the operator between the two machines.
To achieve top placement performance, fit the first machine in a SIPLACE X-Series S line with a input conveyor extension and the last
machine in the line with an output conveyor extension.
CPP_H = Multistar CPP in high assembly position
CPP_L = Multistar CPP in low assembly position

3 Technical data and assemblies User manual SIPLACE X-Series
3.1 Performance data From software version 710.0 Edition 12/2016
116
3.1.7 SIPLACE X2 S machine performance
3
Placement head types SIPLACE SpeedStar (C&P20)
SIPLACE SpeedStar (C&P20 P)
SIPLACE MultiStar (CPP)
SIPLACE TwinStar (TH)
Placement performance
SIPLACE X2 S
For a definition of placement performance values, see the note on page 111.
Machine Placement area 1 Placement area 2 IPC value Benchmark
value
Theoretical
value
X2 S-A C&P20 C&P20 45,000 54,000 68,200
C&P20 CPP_L 40,200 49,500 64,900
C&P20 CPP_H 38,250 46,500 59,900
C&P20 P C&P20 P 52,000 62,500 85,250
C&P20 P CPP_L 45,500 53,750 73,300
C&P20 P CPP_H 43,000 50,750 69,220
CPP_L CPP_L 37,400 45,000 61,600
CPP_H CPP_H 33,500 39,000 55,500
CPP_L CPP_H 35,450 42,000 57,900
X2 S-B C&P20 TH 27,000 32,000 40,750
C&P20 P TH 30,800 36,250 49,450
CPP_L TH 24,000 27,500 37,450
CPP_H TH 20,600 24,500 32,900
X2 S-C TH TH 9,000 10,000 13,000
Important notes
When setting up a machine (S; F, HS, HF, X or D-Series) next to a SIPLACE X-Series, be aware that there is limited room
between the two machines. In these cases, use a suitable conveyor extension to create room of 0.5m for the operator between
the two machines.
To achieve top placement performance, fit the first machine in a SIPLACE X-Series S line with a input conveyor extension and
the last machine in the line with an output conveyor extension.
CPP_H = Multistar CPP in high assembly position
CPP_L = Multistar CPP in low assembly position