3 Technical data and assemblies User manual SIPLACE X-Series 3.2 Ambient conditions and connection values From software version 710.0 Edition 12/2016 120 3.2 Ambient conditions and connection values 3.2.1 Ambient conditi…

100%1 / 416
User manual SIPLACE X-Series 3 Technical data and assemblies
From software version 710.0 Edition 12/2016 3.1 Performance data
119
3.1.10 Component supply
3
Tape reel diameter
Standard
Maximum
to 432 mm (17“)
483 mm (19“)
Max. component supply
4 component trolleys X on the SIPLACE X2 S / X3 S / X4 S
4 component trolleys X on the SIPLACE X4i S
4 component trolleys X on the SIPLACE X4 S micron
4 component trolleys X on the SIPLACE X4i S micron
160 feeder modules, each with 8 mm X
148 feeder modules, each with 8 mm X
160 feeder modules, each with 8 mm X
148 feeder modules, each with 8 mm X
Component trolley changeover time < 1 minute
Feeder module types (SIPLACE X) with adapter Tape feeder modules, reject conveyors, stick
magazine and label presenters.
Important notes
When setting up a machine (S; F, HS, HF, X or D-Series) next to a SIPLACE X-Series, be aware that there is limited room between the two
machines. In these cases, use suitable conveyor extensions to create room of 0.5m for the operator between the two machines.
To achieve top placement performance, fit the first machine in a SIPLACE X-Series line with an input conveyor extension and the last
machine in the line with an output conveyor extension.
3 Technical data and assemblies User manual SIPLACE X-Series
3.2 Ambient conditions and connection values From software version 710.0 Edition 12/2016
120
3.2 Ambient conditions and connection values
3.2.1 Ambient conditions for packaging, transportation and storage
3
3.2.2 Ambient conditions for machine operation
3
Temperature range Between -25°C and 55°C
Atmospheric humidity Up to 95%
Ambient pressure Up to 3000 m height without pressure equalization
Room temperature Between 15°C and 35°C
Atmospheric humidity 30% to 75%
(on average not higher than 45%, so that there is no risk of
condensation on the machine.)
Ambient pressure > 750 mbar (corresponds to 2500 m above mean sea level)
User manual SIPLACE X-Series 3 Technical data and assemblies
From software version 710.0 Edition 12/2016 3.2 Ambient conditions and connection values
121
3.2.3 Electrical ratings and energy consumption
3
3
PLEASE NOTE
Use of a residual current protection device
The low ground leakage current of the system makes it possible to use an upstream
residual current protection device at the customer end. This must be all-current sen-
sitive (RCD type B).
SIPLACE X2 S
Electrical ratings
Supply voltage Fuse
Main power supply 3 x 360 V~ to 3 x 480 V~ ± 10 %; 50/60 Hz
3 x 200 V~ to 3 x 240 V~ ± 10 %; 50/60 Hz
*a
3 x 16A characteristic C
3 x 16A characteristic C
*b
Mains power con-
nection
Cable 5 x 4 mm² with CEKON connector (3 x 360 V~ to 3 x 480 V~)
Cable 5 x 4 mm² (3 x 200 V~ to 3 x 240 V)
Energy consumption
With a vacuum pump
*c
With two vacuum pumps
b
Without vacuum pumps
*d
Nominal apparent
power
2.7 kVA -- 1.4 kVA
Nominal active
power
1.8 kW -- 1.1 kW
SIPLACE X3 S
Electrical ratings
Supply voltage Fuse
Main power supply 3 x 360 V~ to 3 x 480 V~ ± 10 %; 50/60 Hz
3 x 200 V~ to 3 x 240 V~ ± 10 %; 50/60 Hz
a
3 x 16A characteristic C
3 x 16 A characteristic C
*b
Mains power con-
nection
Cable 5 x 4 mm² with CEKON connector (3 x 360 V~ to 3 x 480 V~)
Cable 5 x 4 mm² (3 x 200 V~ to 3 x 240 V)
Energy consumption
With one vacuum pump
b
With two vacuum pumps
b
Without vacuum pumps
c
Nominal apparent
power
2.7 kVA 4.1 kVA 1.4 kVA
Nominal active
power
1.8 kW 2.6 kW 1.1 kW
*)a With options package
*)b e.g. Siemens circuit breakers in accordance with IEC and UL 489 (order no.: 5SJ4 316-7HG42)
or
EATON Industries circuit breaker FAZ-C16/3-NA 16A 3p (UL 489, CSA C22.2 no. 5, IEC 60947-2)
*)c Vacuum pump for C&P20 head only.
*)d Optional