User manual SIPLACE X-Series 5 Working with the machine From software version 710.0 Edition 12/2016 5.7 Indicator lamps with horn 279 5.7.2.1 Basics 5 5.7.2.2 Frequency of flashes 5 5 The machine is performing a manual f…

5 Working with the machine User manual SIPLACE X-Series
5.7 Indicator lamps with horn From software version 710.0 Edition 12/2016
278
A board needs to be taken out
of the output conveyor (e.g. for
inspection).
Respective side White: 500 -500
Green: 700 -700
Horn: On
Red: Off
Yellow: Off
Green: Flashes
Horn: On
The PCB conveyor is jammed
(successor machine is waiting
for boards).
Respective side Not configured Red: Off
Yellow: Off
Green: Flashes
Horn: Off
More than one pickup position
with the same components is
disabled but there is more than
one pickup position available
for use.
Respective side White: 500 -500
Green: Off
Horn: Off
Red: Off
Yellow: On
Green: On
Horn: Off
Setup verification is required
for at least one pickup position.
Respective side White: 500 -500
Green: Off
Horn: Off
Red: Off
Yellow: Flashes
Green: Off
Horn: Off
The nozzle setup is not com-
plete.
Respective side White: 500 -500
Green: Off
Horn: Off
Red: Off
Yellow: On
Green: On
Horn: Off
The last available pickup posi-
tion is being used or there is no
pickup position left for this com-
ponent. The machine will con-
tinue to produce while there are
still other components which
can be placed.
Respective side White: 100 -200
Green: Off
Horn: Off
Red: Off
Yellow: On
Green: On
Horn: Off
The filling level of the pickup
position or dipping module is
low.
Respective side White: 100 -200
Green: Off
Horn: Off
Red: Off
Yellow: On
Green: On
Horn: Off
The machine has been auto-
matically stopped due to a non-
configured event e.g. conveyor
error. Events which have not
been configured and which
could lead to a machine stop
have not be taken into consid-
eration here.
Respective side White: On
Green: Off
Horn: Off
Red: Off
Yellow: Flashes
Green: Off
Horn: Off
The production has been auto-
matically stopped (e.g. there is
no component ready for pick-
up).
Respective side White: On
Green: Off
Horn: Off
Red: Off
Yellow: Flashes
Green: Off
Horn: Off
Meaning Machine side Status - two color
(white/green)
Status - three color
(red/yellow/green)

User manual SIPLACE X-Series 5 Working with the machine
From software version 710.0 Edition 12/2016 5.7 Indicator lamps with horn
279
5.7.2.1 Basics
5
5.7.2.2 Frequency of flashes
5
5
The machine is performing a
manual function triggered by
the operator.
Both sides White: 100 -1000
Green: 700 - 700
Horn: Off
Red: Off
Yellow: Off
Green: Flashes
Horn: Off
Unable to move one of the
boards to the next area.
Respective side Not configured Red: Off
Yellow: Flashes
Green: Off
Horn: Off
The machine has been stopped
due to a fiducial measurement
error ( z. B. board, table, feeder
module).
Both sides White: On
Green: Off
Horn: Off
Red: Off
Yellow: Flashes
Green: Off
Horn: Off
The safety loop has not closed. Respective side White: On
Green: Off
Horn: Off
Red: On
Yellow: Off
Green: Off
Horn: Off
The machine reports a ma-
chine error.
Respective side
or both sides
White: On
Green: Off
Horn: On
Red: On
Yellow: Off
Green: Off
Horn: On
Meaning Machine side Status - two color
(white/green)
Status - three color
(red/yellow/green)
Status Meaning
Off No warning and no alert
Flashes Warning, the frequency varies depending on the type of warning
On Alert
Normal flashing Green indicator lamp: 700 ms off, 700 ms on
White indicator lamp: 500 ms off, 500 ms on
Short flashing 100 ms off, 1000 ms on
Fast flashing 100 ms off, 200 ms on

5 Working with the machine User manual SIPLACE X-Series
5.7 Indicator lamps with horn From software version 710.0 Edition 12/2016
280
5.7.2.3 Priorities
5
5.7.2.4 Reaction time
Each change to the machine status is shown at the indicator lamps within three seconds.
Type of warning Priority
Definition for fast flashing Top
Definition for normal flashing Medium
Definition for short flashing Lowest