00197902-03_UM_X-Serie-S_EN - 第280页

5 Working with the machine User manual SIPLACE X-Series 5.7 Indicator lamps with horn From softwa re version 710.0 Edition 12/2016 280 5.7.2.3 Priorities 5 5.7.2.4 Reaction time Each change to the machine st atus is show…

100%1 / 416
User manual SIPLACE X-Series 5 Working with the machine
From software version 710.0 Edition 12/2016 5.7 Indicator lamps with horn
279
5.7.2.1 Basics
5
5.7.2.2 Frequency of flashes
5
5
The machine is performing a
manual function triggered by
the operator.
Both sides White: 100 -1000
Green: 700 - 700
Horn: Off
Red: Off
Yellow: Off
Green: Flashes
Horn: Off
Unable to move one of the
boards to the next area.
Respective side Not configured Red: Off
Yellow: Flashes
Green: Off
Horn: Off
The machine has been stopped
due to a fiducial measurement
error ( z. B. board, table, feeder
module).
Both sides White: On
Green: Off
Horn: Off
Red: Off
Yellow: Flashes
Green: Off
Horn: Off
The safety loop has not closed. Respective side White: On
Green: Off
Horn: Off
Red: On
Yellow: Off
Green: Off
Horn: Off
The machine reports a ma-
chine error.
Respective side
or both sides
White: On
Green: Off
Horn: On
Red: On
Yellow: Off
Green: Off
Horn: On
Meaning Machine side Status - two color
(white/green)
Status - three color
(red/yellow/green)
Status Meaning
Off No warning and no alert
Flashes Warning, the frequency varies depending on the type of warning
On Alert
Normal flashing Green indicator lamp: 700 ms off, 700 ms on
White indicator lamp: 500 ms off, 500 ms on
Short flashing 100 ms off, 1000 ms on
Fast flashing 100 ms off, 200 ms on
5 Working with the machine User manual SIPLACE X-Series
5.7 Indicator lamps with horn From software version 710.0 Edition 12/2016
280
5.7.2.3 Priorities
5
5.7.2.4 Reaction time
Each change to the machine status is shown at the indicator lamps within three seconds.
Type of warning Priority
Definition for fast flashing Top
Definition for normal flashing Medium
Definition for short flashing Lowest
User manual SIPLACE X-Series 5 Working with the machine
From software version 710.0 Edition 12/2016 5.8 Shift changeover
281
5.8 Shift changeover
5.8.1 Shift changeover tasks
Splice the tapes early. The feeder modules do not have to be refilled as soon as the new shift
starts. This minimizes extended down times.
At the shift change, pass important information on to the next operator. This includes, for in-
stance, changes to the placement program. Also read through the list of the descriptions of
the steps to take in section 5
, page 303.
Carry out a setup check.
Make sure that the feeder modules are equipped with the correct components, that they are
at the correct locations in the component trolley and that the conveyor increment is set cor-
rectly.
Clean the following line assemblies:
Empty the reject bin and carefully vacuum the area around the reject bin.
Carefully vacuum the nozzle changer, feeder modules and the component trolley.
Empty the waste tape container. Follow the safety instructions given in section 5.8.2, page
282
.
Empty the tray for the machine cover.