00197902-03_UM_X-Serie-S_EN - 第332页
6 Station extensions User manual SIPLACE X-Series 6.1 Nozzle changer From software version 710.0 Edition 12/2016 332 6.1.4.2 Nozzle changer for the CPP with 4 maga zines Item no. 001 19742-xx Nozzle changer fo r CPP - sh…

User manual SIPLACE X-Series 6 Station extensions
From software version 710.0 Edition 12/2016 6.1 Nozzle changer
331
6.1.4 Nozzle changer for the SIPLACE MultiStar CPP
6.1.4.1 Nozzle changer for the CPP with 6 magazines
Item no. 00119741-xx Nozzle changer for CPP - long
or
Item no. 03103514-xx Nozzle changer basic assembly CP/all - long
6
Fig. 6.1 - 14 Nozzle changer for the SIPLACE MultiStar with 6 magazines
(1) Nozzle magazine for 20xx nozzles
(2) Nozzle magazine for 28xx nozzles
The magazines are fitted onto a common carrier pate, are fixed with two cylinder pins and fas-
tened with 4 push buttons. The exact position is determined with two fiducials on each magazine.
The correct seat of the magazines on the carrier plate is monitored by microswitches, to prevent
a collision of the placement head with any magazines projecting upwards. All 6 magazine loca-
tions must be filled since the safety circuit stops the machine in response to missing magazines
or magazines that are not seated correctly. The nozzle changer recognizes whether the nozzle
magazine is for 20xx nozzles or for 28xx nozzles by the nozzle magazine code.
At the nozzle station, components can be rejected with an air blast by the nozzles. Nozzles can
be stripped off there and disposed of in the reject bin.

6 Station extensions User manual SIPLACE X-Series
6.1 Nozzle changer From software version 710.0 Edition 12/2016
332
6.1.4.2 Nozzle changer for the CPP with 4 magazines
Item no. 00119742-xx Nozzle changer for CPP - short
or 6
Item no. 03103649-xx Nozzle changer basic assembly CP/all - short
6
Fig. 6.1 - 15 Nozzle changer for the SIPLACE MultiStar with 4 magazines
(1) Nozzle magazine for 20xx nozzles
(2) Nozzle magazine for 28xx nozzles
The magazines are fitted onto a common carrier pate, are fixed with two cylinder pins and fas-
tened with 4 push buttons. The exact position is determined with two fiducials on each magazine.
The correct seat of the magazines on the carrier plate is monitored by microswitches, to prevent
a collision of the placement head with any magazines projecting upwards. All 4 magazine loca-
tions must be filled since the safety circuit stops the machine in response to missing magazines
or magazines that are not seated correctly. The nozzle changer recognizes whether the nozzle
magazine is for 20xx nozzles or for 28xx nozzles by the nozzle magazine code.
At the nozzle station, components can be rejected with an air blast by the nozzles. Nozzles can
be stripped off there and disposed of in the reject bin.

User manual SIPLACE X-Series 6 Station extensions
From software version 710.0 Edition 12/2016 6.1 Nozzle changer
333
6.1.4.3 Nozzle magazine with 12 garages for 20xx nozzles
6
Fig. 6.1 - 16 Nozzle magazine for 20xx nozzles - locking plate open
(1) 12 garages for 20xx nozzles
(2) Fiducials (only visible when locking plate open)
(3) Locking plate