NPM
Maintenance Edition
9.7 Placement Load
EJM9BE-MB-09M-21 Page 9-35
16
Turn OFF the servo switch.
17
Open the safety cover.
18
Attach the nozzle.
∗
Attach the nozzle to the target nozzle position
for measurement.
Use the No.1003 nozzle.
19
Close the safety cover.
20
Turn ON the servo switch.
21
Press + [OK].
22
Press + [Load meas(F1)].
•
The calibration is carried out.
UnitCalibHeadLoad-06E01
21
UnitCalibHeadLoad-07E01
22

NPM
Maintenance Edition
9.7 Placement Load
Page 9-36 EJM9BE-MB-09M-21
23
Check that it is successfully complete.
24
Press the numeric value.
•
The numeric keypad window opens.
25
Enter the measured value.
∗
Enter the numeric value indicated on the load
measuring jig.
Input range: 3.2 N to 6.2 N
26
Press + [Load meas(F2)].
•
The calibration is carried out.
UnitCalibHeadLoad-08E01
23
24
UnitCalibHeadLoad-09E01
25
UnitCalibHeadLoad-10E01
26

NPM
Maintenance Edition
9.7 Placement Load
EJM9BE-MB-09M-21 Page 9-37
27
Check that it is successfully complete.
28
Press the numeric value.
•
The numeric keypad window opens.
29
Enter the measured value.
∗
Enter the numeric value indicated on the load
measuring jig.
Input range: 15 N to 25 N
30
Press + [Min load chk].
•
The calibration is carried out.
UnitCalibHeadLoad-11E01
27
28
UnitCalibHeadLoad-12E01
29
UnitCalibHeadLoad-13E01
30