NPM
Maintenance Edition
9.7 Placement Load
EJM9BE-MB-09M-21 Page 9-35
16
Turn OFF the servo switch.
17
Open the safety cover.
18
Attach the nozzle.
Attach the nozzle to the target nozzle position
for measurement.
Use the No.1003 nozzle.
19
Close the safety cover.
20
Turn ON the servo switch.
21
Press + [OK].
22
Press + [Load meas(F1)].
The calibration is carried out.
UnitCalibHeadLoad-06E01
21
UnitCalibHeadLoad-07E01
22
NPM
Maintenance Edition
9.7 Placement Load
Page 9-36 EJM9BE-MB-09M-21
23
Check that it is successfully complete.
24
Press the numeric value.
The numeric keypad window opens.
25
Enter the measured value.
Enter the numeric value indicated on the load
measuring jig.
Input range: 3.2 N to 6.2 N
26
Press + [Load meas(F2)].
The calibration is carried out.
UnitCalibHeadLoad-08E01
23
24
UnitCalibHeadLoad-09E01
25
UnitCalibHeadLoad-10E01
26
NPM
Maintenance Edition
9.7 Placement Load
EJM9BE-MB-09M-21 Page 9-37
27
Check that it is successfully complete.
28
Press the numeric value.
The numeric keypad window opens.
29
Enter the measured value.
Enter the numeric value indicated on the load
measuring jig.
Input range: 15 N to 25 N
30
Press + [Min load chk].
The calibration is carried out.
UnitCalibHeadLoad-11E01
27
28
UnitCalibHeadLoad-12E01
29
UnitCalibHeadLoad-13E01
30