NPM Maint en anc e E di ti on 9.7 Pl ac ement Load Page 9-48 EJM9BE-M B-09M-21 6. Settin g the decim al poi nt posi ti on 1 Set a screen display to ‘dP.’ 2 Press to blink ‘00. 000.’ 3 Press to set a dec im al point (a) a…

100%1 / 99
NPM
Maintenance Edition
9.7 Placement Load
EJM9BE-MB-09M-21 Page 9-47
5. Setting the indicated value 2
1
Set a screen display to ‘dSP.A2.’
2
Press to blink ‘19999.’
3
Press to set the
display to ‘09800.’
4
Press to accept.
EJM4A-421E
EJM4A-423E
EJM4A-424E
EJM4A-422E
NPM
Maintenance Edition
9.7 Placement Load
Page 9-48 EJM9BE-MB-09M-21
6. Setting the decimal point position
1
Set a screen display to ‘dP.’
2
Press to blink ‘00.000.’
3
Press to set a decimal point
(a) at the position ‘00.000.’
4
Press to accept.
5
Hold down for one second or
more.
The operation level returns.
EJM4A-424E
EJM4A-415E
EJM4A-147E
a
EJM4A-147E
NPM
Maintenance Edition
9.8 Line Camera
EJM9BE-MB-09M-21 Page 9-49
9.8 Line Camera
This procedure is common to 12-nozzle, 8-nozzle, and 2-nozzle heads.
If the target table is provided with feeders, remove them beforehand.
1
Press .
2
Press [L-camera].
3
Select a table.
Select the target table for calibration.
4
Press + [H
θ
axis origin].
UnitCalibLineCamera-01E00
1
2
UnitCalibLineCamera-01E00
3
4