9.8 Line Camera
EJM9BE-MB-09M-21 Page 9-51
10
Turn ON the servo switch.
11
Press + [OK].
The calibration is carried out.
For the 12-nozzle head and the 8-nozzle
head, perform step 18 onward.
For the 2-nozzle head, proceed to the
following steps continuously.
12
Turn OFF the servo switch.
13
Open the safety cover.
14
Check the head installation angle.
Check that the nozzle holder claw is on the
left side.
15
Close the safety cover.
Nozzle holder claw
UnitCalibLineCamera-03E00
11
NPM
Maintenance Edition
9.8 Line Camera
Page 9-52 EJM9BE-MB-09M-21
16
Turn ON the servo switch.
17
Press [Yes].
18
Turn OFF the servo switch.
19
Open the safety cover.
20
Relocate the line camera jig.
12-nozzle head
Relocate the line camera jig from the nozzle
position 9
4.
8-nozzle head
Relocate the line camera jig from the nozzle
position 6
3.
2-nozzle head
Relocate the line camera jig from the nozzle
position 1
2.
UnitCalibLineCamera-04E00
17
NPM
Maintenance Edition
9.8 Line Camera
EJM9BE-MB-09M-21 Page 9-53
21
Close the safety cover.
22
Turn ON the servo switch.
23
Press + [OK].
The calibration is carried out.
For the 2-nozzle head, perform steps 12 to 17
again, and proceed to the following steps.
24
Check that it is successfully complete.
25
Press + [Camera offset].
UnitCalibLineCamera-06E00
24
25
UnitCalibLineCamera-05E00
23