NPM Calibration Manual-En - 第56页
NPM Maint en anc e E di ti on 9.8 Li ne Camer a EJM9BE-M B-09M-21 Page 9-55 29 Check that it i s successfu ll y com pl ete. ∗ Perf orm steps 3–32 f or also the ot her tabl e. 30 Press [Jig stat i on]. • W hen exiti ng t …

NPM
Maintenance Edition
9.8 Line Camera
Page 9-54 EJM9BE-MB-09M-21
26
Press + [OK].
•
The head moves to the working position.
27
Check the line camera jig.
12-nozzle head
∗
Check that the line camera jig is attached to
the nozzle position 4.
8-nozzle head
∗
Check that the line camera jig is attached to
the nozzle position 3.
2-nozzle head
∗
Check that the line camera jig is attached to
the nozzle position 2.
28
Press + [OK].
•
The calibration is carried out.
UnitCalibLineCamera-07E00
26
UnitCalibLineCamera-08E00
28

NPM
Maintenance Edition
9.8 Line Camera
EJM9BE-MB-09M-21 Page 9-55
29
Check that it is successfully complete.
∗
Perform steps 3–32 for also the other table.
30
Press [Jig station].
•
When exiting this screen to the other one, you
are always prompted to save the data.
∗
To save the data obtained by the calibration,
press [Yes].
•
If you press [No], the return-to-origin process
is carried out and the data obtained by the
calibration are lost.
•
After the above operation, the next screen is
displayed.
31
Press + [OK].
•
The head moves to the working position.
UnitCalibLineCamera-09E00
29
UnitCalibLineCamera-10E00
30
UnitCalibLineCamera-11E00
31

NPM
Maintenance Edition
9.8 Line Camera
Page 9-56 EJM9BE-MB-09M-21
32
Turn OFF the servo switch.
33
Open the safety cover.
34
Remove the jig nozzle.
35
Close the safety cover.
36
Turn ON the servo switch.
37
Press + [OK].
•
After the head moves to the origin position,
the screen selected in step 33 is displayed.
UnitCalibLineCamera-12E00
37