NPM Maint en anc e E di ti on 9.10 3D Camer a EJM9BE-M B-09M-21 Page 9-67 10 Set the j ig station. ∗ Set t he jig com ponents and the light lumi nosit y ji g ont o the j i g stat i on bef orehand. Ji g stati on ∗ Set t h…

NPM
Maintenance Edition
9.10 3D Camera
Page 9-66 EJM9BE-MB-09M-21
6
Press + [Run].
•
The conveyor width is adjusted to 215 mm.
7
Press + [OK].
•
The head moves to the retraction position.
∗
After the head is moved, set the jig station.
8
Turn OFF the servo switch.
9
Open the safety cover.
UnitCalibCamera3D-14E00
6
UnitCalibCamera3D-02E00
7

NPM
Maintenance Edition
9.10 3D Camera
EJM9BE-MB-09M-21 Page 9-67
10
Set the jig station.
∗
Set the jig components and the light
luminosity jig onto the jig station beforehand.
Jig station
∗
Set the jig station with its end fit to the
reference mark on the upper surface of the
front rail.
11
Turn ON the power supply switch of
the jig station.
∗
Check that the LED lamp on the power supply
switch is lit.
Jig station
Reference mark
In left right flow
Reference mark
In right left flow
Jig component
Light luminosity jig
Power supply switch
(LED lamp)
∗
As shown in the left photo, place the jig
component and light luminosity jig to the
jig station.
These jigs have no particular orientation.

NPM
Maintenance Edition
9.10 3D Camera
Page 9-68 EJM9BE-MB-09M-21
12
Close the safety cover.
13
Turn ON the servo switch.
14
Press + [OK].
•
The head moves to the working position.
15
Set the nozzle.
•
When the head has returned to the working
position, set the nozzle.
16
Attach the nozzle.
8-nozzle head
∗
Attach the No.184 nozzle to the nozzle
positions 3 and 6.
2-nozzle head
∗
Attach the No.1003 nozzles to all the nozzle
positions.
17
Close the safety cover.
18
Turn ON the servo switch.
UnitCalibCamera3D-03E00
14