NPM Maint en anc e E di ti on 9.13 T ray EJM9BE-M B-09M-21 Page 9-85 14 Check that it i s successfu ll y com pl ete. 15 Press . • W hen exiti ng t his s cr een to t he other one, you are al ways prompt ed t o sa v e the …

NPM
Maintenance Edition
9.13 Tray
Page 9-84 EJM9BE-MB-09M-21
9
Press + [OK].
•
The calibration is carried out.
10
Check that it is successfully complete.
11
Press + [Pickup pos. 1].
•
The calibration is carried out.
12
Check that it is successfully complete.
13
Press + [Pickup pos. 2].
•
The calibration is carried out.
UnitCalibTrayPos-02E00
9
UnitCalibTrayPos-03E00
10
11
UnitCalibTrayPos-04E00
12
13

NPM
Maintenance Edition
9.13 Tray
EJM9BE-MB-09M-21 Page 9-85
14
Check that it is successfully complete.
15
Press .
•
When exiting this screen to the other one, you
are always prompted to save the data.
∗
To save the data obtained by the calibration,
press [Yes].
•
If you press [No], the return-to-origin process
is carried out and the data obtained by the
calibration are lost.
•
After the above operation, the next screen is
displayed.
16
Press + [OK].
•
The head moves to the retraction position.
UnitCalibTrayPos-06E00
15
UnitCalibTrayPos-05E00
14
UnitCalibTrayPos-07E00
16

NPM
Maintenance Edition
9.13 Tray
Page 9-86 EJM9BE-MB-09M-21
17
Turn OFF the servo switch.
18
Open the safety cover.
19
Detach the nozzles.
20
Close the safety cover.
21
Turn ON the servo switch.
22
Press + [OK].
•
After the head moves to the origin position,
the screen selected in step 16 is displayed.
UnitCalibTrayPos-08E00
22