1OM-1505-004_w - 第106页

1OM-1505 1. Automatic Operation : Chap.3 3-1 1002-002 1. Automatic Operation The automatic operation flow is as follows. Program Change Operation Refer to "Chapter 4" for details. Inspections before 1.1.1 Conrm…

100%1 / 217
1OM-1505
0906-001 3-B
1OM-1505
1. Automatic Operation : Chap.3
3-11002-002
1. Automatic Operation
The automatic operation flow is as follows.
Program Change Operation Refer to "Chapter 4" for details.
Inspections before 1.1.1 Conrmation of Power Supply
Automatic Operation 1.1.2 Conrmation of Air Pressure
1.1.3 Cover Section Check
1.1.4 Safety Check for Surrounding Area of the
Machine
Preparation before
1.2.1 Power Input
Automatic Operation 1.2.2 Preparation for Solder Paste
Start of Automatic Operation 1.3.1 Starting the System Program
1.3.2 Login Operation
1.3.3 Login Operation
1.3.4 Work during Automatic Operation
Materials and PCB 2. Squeegee Replacement and Solder Paste
Replenishment Replenishment
3. PCB Replenishme
nt
Automatic Operation Stop, 4.1 Automatic Operation Sto
Interruption and Re-start 4.2 Interruption of Automatic Operation
4.3 Automatic Operation Re-Start
End of Automatic Operation 1.4.1 Stop of Automatic Operation
1.4.2 Logout
Automatic operation ow F1C1
1OM-1505
3-2
1. Automatic Operation : Chap.3
1.1 Inspections before Automatic Operation
1.1.1 Conrmation of Power Supply
Conrm that the main breaker (connected to this machine) in the factory is set to
"ON".
·
Voltage : 200±20 V AC, 3-Phase
·
Apparent Power : Approx. 7.7 kVA or less)
1.1.2 Conrmation of Air Pressure
Conrm that the air pressure is set to the value specied below.
·
Main Pressure : 0.45 MPa (4.6 kgf/cm
2
)
Note
Never adjust the pressure.
The pressure switch is already set to "0.4MPa (4.1 kgf/cm
2
).
Main Pressure
0.45 MPa (4.6 kgf/cm
2
)
F1C2
Notice
(a) Do not change the set air pressure. Otherwise, the pneumatic
devices will not work normally.
(b) Use of Dry and Clean Air
Be sure to use dry and clean air.
If moisture, oil, dust, etc., enter a pneumatic device (air cylinder,
etc.,) used in this machine, it will result in a breakdown of the
machine.
Note
Dry and Clean Air:
Moisture : Dew Point -17° or lower (Atmospheric Pressure)
Oil : 0.1 mg/m
3
or less (ANR)
Dust : Solid Material 0.01 mm or less
0906-001