1OM-1505-004_w - 第108页

1OM-1505 1. Automatic Operation : Chap.3 3-3 1.1.3 Cover Section Check DANGER There are strong motorized and high-voltage areas inside the machine. Special caution should be paid not to touch them. Doing otherwise will c…

100%1 / 217
1OM-1505
3-2
1. Automatic Operation : Chap.3
1.1 Inspections before Automatic Operation
1.1.1 Conrmation of Power Supply
Conrm that the main breaker (connected to this machine) in the factory is set to
"ON".
·
Voltage : 200±20 V AC, 3-Phase
·
Apparent Power : Approx. 7.7 kVA or less)
1.1.2 Conrmation of Air Pressure
Conrm that the air pressure is set to the value specied below.
·
Main Pressure : 0.45 MPa (4.6 kgf/cm
2
)
Note
Never adjust the pressure.
The pressure switch is already set to "0.4MPa (4.1 kgf/cm
2
).
Main Pressure
0.45 MPa (4.6 kgf/cm
2
)
F1C2
Notice
(a) Do not change the set air pressure. Otherwise, the pneumatic
devices will not work normally.
(b) Use of Dry and Clean Air
Be sure to use dry and clean air.
If moisture, oil, dust, etc., enter a pneumatic device (air cylinder,
etc.,) used in this machine, it will result in a breakdown of the
machine.
Note
Dry and Clean Air:
Moisture : Dew Point -17° or lower (Atmospheric Pressure)
Oil : 0.1 mg/m
3
or less (ANR)
Dust : Solid Material 0.01 mm or less
0906-001
1OM-1505
1. Automatic Operation : Chap.3
3-3
1.1.3 Cover Section Check
DANGER
There are strong motorized and high-voltage areas
inside the machine. Special caution should be
paid not to touch them. Doing otherwise will cause
personal injury (serious accident).
Only qualied maintenance personnel should
detach the covers.
The machine should be operated with the covers
being attached.
If a cover is detached, be sure to reattach it.
Be sure to transparent covers before operating the
machine.
Do not disengage the interlock mechanism of the
transparent covers (door type).
Conrm that the transparent covers on the upper section of the machine and safety
doors around the base Maintenance Shutter have been closed.
Safety Cover
Maintenance
Shutter
Front Side of MachineRear Side of Machine
Transparent Cover
Cover Lock Switch
F1C3
1002-002
1OM-1505
3-4
1. Automatic Operation : Chap.3
1.1.4 Safety Check for Surrounding Area of the Machine
Before starting the operation, perform the safety check for the surrounding area of
the machine.
CAUTION
Before starting the automatic operation, check carefully
that there is no person around the machine (especially on
the other side of the machine operation). Make sure that
no objects (tools, parts, etc.) are left behind.
0906-001