1OM-1505-004_w - 第136页

1OM-1505 3. Program Change Operation: Chap.4 4-7 PCB Backup Jig Front Side of Machine PCB Backup Jig Operations F1D4-2 3.4.3 In the case that other jig is used: When other jig is used, consult with Sales Dept., in Hitach…

100%1 / 217
1OM-1505
4-6
3. Program Change Operation: Chap.4
3.4 Backup Pin Adjustment and PCB Backup Jig or PCB
Vacuum Jig Installation
This section describes the backup pin installation position adjustment and the
installation of the PCB backup jig or PCB vacuum jig prepared for the product
model.
3.4.1 In the case that the Backup Pins are used:
Stand the backup pins on the well-balanced positions where these backup pins
can support the PCB securely in the printing operation and they do not hinder the
printing operation.
Note
When the backup pins are arranged on the positions out of the PCB or
unbalanced positions, the printing operation might not be available.
3.4.2 In the case that the PCB Backup Jig or PCB Vacuum Jig is used:
Set the PCB backup jig on the backup plate hole position and insert the pilot pins.
Note
When the PCB vacuum jig is used, remove the plug from the vacuum hole.
Front Side of Machine
Vacuum Hole
Backup Plate
F1D4
Backup Jig or Vacuum Jig
Pilot Pins
F1D4-1
1002-002
1OM-1505
3. Program Change Operation: Chap.4
4-7
PCB Backup Jig
Front Side of Machine
PCB Backup Jig Operations F1D4-2
3.4.3 In the case that other jig is used:
When other jig is used, consult with Sales Dept., in Hitachi High-Technologies or
our sales agent.
1002-002
1OM-1505
4-8
3. Program Change Operation: Chap.4
3.5 PEC Recognition Test
The PEC recognition test for the product PCB is performed in the "PEC Recog.
Test" tab sheet (Operation Sequence: [Maint.] button in the main menu
"DEVICE TEST" button
"PEC Recog. Test" tab).
Reference
Refer to "7.1 PEC Recognition Test" in "Chapter 1 (Vol. 3)" for details.
3.6 2 Camera AUTO Calibration
The ne adjustment for the positions of the PEC recognition camera and stencil
recognition camera are performed using the [2 Camera Auto Calibration] button in
the "Semi-Auto Opn." tab sheet (Operation Sequence: "Setup"
"INDIVIDUAL
SET-UP"
"Semi-Auto Opn." tab).
Reference
Refer to "5.1 Semi-Auto Opn." in "Chapter 3 (Vol. 2)" for details.
1002-002