1OM-1505-004_w - 第21页
3. Alert Indications in Instruction Manual The following summarizes the precautionary items and the location of alert indications in the instruction manual. Alert Description Pages There are strong motorized and high-vol…

Notes on Installation, Transfer and Maintenance
Do not install or transfer the machine on the customer side after shipment.
To ensure perfect operation of the machine, including safety and accuracy, only our
installation service department will install the machine or transfer it to another place.
Only the maintenance work on items described in this ma
nual should be performed by
the customer. Please read the instruction manual carefully before maintenance work.
Do not perform any maintenance work on items that are not described in this manual.
Otherwise, not only breakdown of the machine but also personal injury may result.
When an alert label has deteriorated and become illegible
, contact our service
department.
Only a well-trained service person should perform maintenance work carefully
through for the machine in compliance with the instructions.
Before the maintenance work, be sure to turn of
f the power breaker and lock
them with padlocks.
Designate a person who can have charge of the padlock key.
If the provided padlock is lost or damaged, purchase its substitute.
Even when the power breaker is set to "OFF", the primary line is powered,
making it possible to cause an electric shock.
Be sure to completely stop the power supply to the machine before maintenance work.
Residual voltages may remain behind for a few minu
tes in the internal devices
of the machine after power interception.
Before performing maintenance work, wait until the char
ge lamps of the DC power
supply and the servoamplifier go "OFF" in 10 minutes or more after the power breaker
is set to "OFF".
Safe-7
Safety Precautions
1OM-1505
2. Common Precautionary Items
0906-001

3. Alert Indications in Instruction Manual
The following summarizes the precautionary items and the location of alert indications in
the instruction manual.
Alert Description Pages
There are strong motorized and high-voltage areas
inside the machine. Special caution should be paid not
to touch them. Doing otherwise will cause personal injury
(serious accident).
•
Onlyqualied
maintenancepersonnelshoulddetach
the covers.
•
The machine should be operated with the covers
being attached.
•
If a cover is detached, be sure to reattach it.
•
Be sure to transparent covers before operating the
machine.
•
Do not disengage the interlock mechanism of the
covers.
"2.4" in
"Chapter 1 (Vol.1)"
and "1.1.3" in
"Chapter 3 (Vol. 1)"
With the exception of industrial use alcohol, do not use
cleaning solvents.
In particular, be sure not to use gasoline by mistake as it
ishighlyflammable.
"4.4" in
"Chapter 1 (V
ol.4)"
Alert Indications described as "
DANGER
"
Safe-8
Safety Precautions
1OM-1505
3. Alert Indications in Instruction Manual
0906-001

Alert Indications described as "
WARNING
"
Alert Description Pages
Be sure to keep the all doors closed to avoid any danger
when the automatic operation is started or during the
automatic operation.
"2.4" in
"Chapter 1 (Vol.1)"
Before performing maintenance work, etc., shut off the
power breaker and lock the power breaker with the
padlock.
"2.5" in
"Chapter 1 (Vol.1)"
Only a well-trained service person should perform
maintenance work carefully through for the machine in
compliance with the instructions.
"1.1" in
"Chapter 1 (Vol.4)"
Before the maintenance work, be sure to turn off the
power breaker and lock them with padlocks.
Designate a person who can have charge of the padlock
key.
If the provided padlock is lost or damaged, purchase its
substitute.
"1.1" in
"Chapter 1 (Vol.4)"
As
industrialalcohol
isflammable,besuretokeepit
awayfromanypossiblesourcesofreasitislikelyto
igniteandstartare.
•
Keepindustrial
alcoholawayfromanyheatofre.
•
Avoidsmokingandusingrewhennearthedevice.
"2.1" in
"Chapter 1 (Vol.4)"
To avoid solvent spills, be sure to use the replenishment
container equipped with a nozzle.
•
If you have spilt solvent by mistake, clean it up with a
rag as soon as possible.
•
Aftercleaning
upthespiltsolvent,conrmthatithas
dried completely and enough ventilation is provided.
After that, turn on the power switch of the machine.
"4.4" in
"Chapter 1 (Vol.4)"
When the cap is loose, the internal lid may blow off,
causing the industrial alcohol to drip out. The spill may
alsocausea
re.
Tighten the cap of the tank securely.
"4.4" in
"Chapter 1 (Vol.4)"
Safe-9
Safety Precautions
1OM-1505
3. Alert Indications in Instruction Manual
0906-001