00192792-02 - 第69页

SIPLACE 80 S-25 HM 2 Retrofitting Instructions: Matrix Tray Changer MTC on S-25 HM (Option) 01/01 Issue 2.7 Installing the Retrofit Kit 69 W ARNUNG T o prote ct agains t manipul ation whi ch will cau se mater ial dama ge…

100%1 / 100
2 Retrofitting Instructions: Matrix Tray Changer MTC on S-25 HM (Option) SIPLACE 80 S-25 HM
2.7 Installing the Retrofit Kit 01/01 Issue
68
DANGER
Starting at this point, handling the cutter is particularly DANGEROUS!
Do not reach into the empty-tape duct from above or into the cutter from below.
Å Turn the compressed air ON at the main valve of the compressed air unit. Turn the machine
ON.
Å Actuate the manual valve on the left on the component table.
Å Make certain that the table is in optimal contact with the "Rail, component table".
WARNING: Placement head CRASH
If the component table is NOT in optimal contact, i.e., the centering piece has not been moved in
the maximum distance, damage to the placement head may result.
Å Securely tighten the two screws fastening the "Rail, component table", RH side (see Fig.
2.7.3).
Å Briefly move the component changeover table back out and then right back in.
Å Lower the component table to test whether the "Rail, component table" is in optimal position,
i.e., the table FDQ EHPRYHG LQ Z LWK QR PHFKDQLFDO EORFNDJH DQG LV LQRSWLPDOFRQW DFW RQ
ERWK VLGHV. If necessary, re-loosen the 2 fastening screws and correct the angular position of
the "Rail, component table". Then tighten the two screws -> Note the following CAUTION text.
$IW7KHQ$IWHUZDUGVWLJKWHQ ERWKVFUHZ
SIPLACE 80 S-25 HM 2 Retrofitting Instructions: Matrix Tray Changer MTC on S-25 HM (Option)
01/01 Issue 2.7 Installing the Retrofit Kit
69
WARNUNG
To protect against manipulation which will cause material damage: As a final step, apply the
screw-locking compound RED to the two screws used to fasten the "Rail, component table".
Å Mount the slide rail, RH (black plastic part) with the 2 socket hex head cap screws M6 (size 5)
as shown in Fig. 2.6.5.
 0RXQWLQJDQG$OLJQLQJWKH1HZ+ROGHUIRU1R]]OH&KDQJHU07&
.H\ 
1. Screws fastening the holder for the nozzle changer MTC:
3 socket hex head cap screws M6
2. 2 centering pins (already mounted)
Å Now mount the new holder for the nozzle changer MTC from the retrofit kit, Item no.
00357127-01:
Hold the holder against the machine frame (the RH link is resting on the frame) as shown
above and tighten the holder securely with the 3 socket hex head cap screws M6 (size 5).
The two parallel pins m6x6 are already inserted.
2 Retrofitting Instructions: Matrix Tray Changer MTC on S-25 HM (Option) SIPLACE 80 S-25 HM
2.7 Installing the Retrofit Kit 01/01 Issue
70
.H\
1. 2 socket hex head cap screws M6
2. 1 socket hex head cap screw M6 on support link
Å Place the spirit level on the contact surface of the carrier for the nozzle changer MTC, as shown
above.
Å If necessary, loosen the fastening screws again and use the spirit level to align the holder for
nozzle changer MTC:
With the holder in this position, first tighten the 2 screws (see Fig. 2.7.6 -> Pos. 1) and then the
screw for Pos. 2.