00192792-02 - 第83页
SIPLACE 80 S-25 HM 2 Retrofitting Instructions: Matrix Tray Changer MTC on S-25 HM (Option) 01/01 Issue 2.8 Installing t he MTC 83 .H\ 1. Hand cr ank 2. Coupling for hand c rank Å If necessa ry , set th e MTC to t he r…

2 Retrofitting Instructions: Matrix Tray Changer MTC on S-25 HM (Option) SIPLACE 80 S-25 HM
2.8 Installing the MTC 01/01 Issue
82
,QVWDOOLQJWKH07&
DANGER:
Severe injury may result if the MTC is handled incorrectly.
Comply with ALL of the safety instructions in the "MTC User Manual" (Item no. 00192318-01).
Carry out all of the steps detailed in the section "Installing the MTC in the
SIPLACE Station" of the MTC User Manual.
Observe the DANGER texts regarding transport in the section "Assembling and Disassembling
the MTC" in the above-mentioned user manual. Under no circumstances is the MTC to be trans-
ported with a pallet truck; this might cause it to tip over.
6HWWLQJWKH+HLJKWDQG0RYLQJWKH07&,QIRUWKH)LUVW7LPH
Å Check the shock and position indicator on the MTC.
They must indicate that the MTC has been transported without error.
Å Check whether the MTC is already set to the required conveyor height.
The following HEIGHTS are possible (each with a tolerance of +10 / -15 mm):
– 950 mm
– 930 mm
– 900 mm
– 830 mm

SIPLACE 80 S-25 HM 2 Retrofitting Instructions: Matrix Tray Changer MTC on S-25 HM (Option)
01/01 Issue 2.8 Installing the MTC
83
.H\
1. Hand crank
2. Coupling for hand crank
Å If necessary, set the MTC to the required conveyor height/starting height (dimensions: see
above), as described in the MTC User Manual.
Å Raise the MTC as high as possible with the hand crank fastened on the right on the MTC (see
Fig. 2.8.1). Turning direction = clockwise.
Å Take all of the cables out of the MTC and place them on the floor such that they won’t jam later
when the MTC is moved into the machine.
Å Carefully move the MTC into the machine.
8VLQJDQ$OLJQPHQW*DXJ HWR$OLJQWKH07&
&RPSO\ZLWKWKHDERYH'$1*(5QRWH
The following sequence is described in abbreviated form.
This sequence must be followed as described in detail in the MTC User Manual.

2 Retrofitting Instructions: Matrix Tray Changer MTC on S-25 HM (Option) SIPLACE 80 S-25 HM
2.8 Installing the MTC 01/01 Issue
84
Å Take the set-up gauge out of MTC tower 1.
Å Insert the set-up gauge into the hole of conveyor section 2 of the MTC that is NEXT TO the
PCB conveyor, as shown below in Fig. 2.8.2.
Å Use the hand crank to lower the MTC slowly (see Fig. 2.8.1) and exactly until the red ring of
the set-up gauge is barely visible (see Fig. 2.8.2).
CAUTION
6WRS
the lowering movement
LPPHGLDWHO\
if the feeler
GRHVQRW
move.
If the feeler does not move, the component changeover table is not in optimal contact with the
"Rail, component table".
The "Rail, component table" may not have been aligned correctly after reassembly, therefore the
centering pieces may not project the maximum distance into the holes.
In this case, move the WPC back out of the machine and repeat the process, beginning by adjust-
ing the height as described in Section 2.8.1.
)LVKH\HRIWKH
DGMXVWPHQWJDXJH
5HGULQJ