2 Retrofitting Instructions: M atrix Tray Changer MTC on S-25 HM (Option) SIPLACE 80 S-25 HM 2.8 Installing t he MTC 01/01 Issue 96 Å W as t he adjust ment of the nozzl e change r holder pe rformed exactly ( see Fig. 2 .…

SIPLACE 80 S-25 HM 2 Retrofitting Instructions: Matrix Tray Changer MTC on S-25 HM (Option)
01/01 Issue 2.8 Installing the MTC
95
Å For both types of nozzle changer, continue as follows:
In the field "Calibration", activate the function "
ZLWK
pickup height (see Fig. 2.8.10) -> Select
"All magazines" (button):
Å The calibration of the nozzle changer follows.
First, the fiducials of the magazines and then the fiducials of the reject box are measured ->
Then the pick-up heights of the individual magazines are ascertained.
Å In conclusion, check the pick-up heights ascertained for EACH magazine individually. Do so
as follows:
Select the magazines in succession by clicking on the relevant button -> Select "Display nozzle
data" each time.
The following screen is displayed:
Å For EACH magazine individually, check the ascertained values in the
ODVWFROXPQ
– The max. permissible tolerance of all values of
DQ\QHLJKERULQJPDJD]LQHV
reciprocally
is +/-10 digits.
– The values of the last column of a magazine must be in the range between 870 to 929 digits.
Å If the values are okay, select "Settings" -> Store machine data".
Å If there are deviations, check the following:

2 Retrofitting Instructions: Matrix Tray Changer MTC on S-25 HM (Option) SIPLACE 80 S-25 HM
2.8 Installing the MTC 01/01 Issue
96
Å Was the adjustment of the nozzle changer holder performed exactly (see Fig. 2.8.2)?
To do this, you have to remove the nozzle changer and, if necessary, correct the setting.
Å Is the mounting surface of the nozzle changer holder satisfactory/clean?
Å Was the nozzle changed correctly? Does the nozzle move sluggishly on the sleeve?
Å After eliminating the cause of the problem, repeat the determination of the pick-up heights,
including checking and storing the values, as described above.
Å In SITEST, continuing working on the calculation of the MTC positions (see
Section 2.8.6).
6,7(670HDVXULQJWKH 07&
Calculate the MTC position as described in Version 502.xx of the SITEST User Manual.
In abbreviation form:
Å Starting from the SITEST main view, select the total reference run (button).
Å Select the ICONS "MTC 1". or "MTC 3" .
depending at which location (1 or 3) the MTC was installed.
If an MTC was installed at both locations, the calibration must be executed for both MTCs in
succession.
Å Select "Calibration" (button).

SIPLACE 80 S-25 HM 2 Retrofitting Instructions: Matrix Tray Changer MTC on S-25 HM (Option)
01/01 Issue 2.8 Installing the MTC
97
Å The display follows: "Function is carried out".
Å Select "Store machine data" and exit the SITEST program.
&RQILJXULQJWKH 2SWLRQ07&DWWKH/LQH&RPSXWHU
Use the software version description LRU 502.01, Item no.: 00192397-01 (G + E)
Å Allocate the name
07&B[B/HYHOV
for the MTC at the line computer
-> see the above-mentioned description, section "New Matrix Tray Changer".
Å Configure the MTC at the line computer starting with SW V502.01:
- in the station editor, if the MTC remains permanently allocated to the station or
- in the setup editor, if the MTC is also reconfigured within the line.
Proceed as detailed in the above-mentioned description.