7-66 Advanced Chip Shooter DECAN S2 Admi nistra t or’s Guide <Dire cti on Mark Parameter> group <T ype> combo box None: The re is no Direc t ion Mark. Triangle: Selec ted when the direction mark is a tria…

7-65
Part Registration
Clicking the <Ex Param> button will display the following dialog box. The value
from 0 up to 10 can be set in the <Body Sub Sample> edit box of the <Extra
Parameter> tab dialog box.
The value set here determines the fineness when creating the outline of the part in
the SM Vision window.
If the image displayed in the SM Vision window has a lot of noise or is unclear, set
its value to the default value of ‘0’.
If the image is clear and therefore the outline of the part can be distinguished
plainly, the part outline can be created with fine detail.
However, if the outline becomes rough due to an over-increase in the value, the
part may not be recognized correctly.
1- Finest Outline
10 –Roughest Outline
1: Polygon Toolbar
Polygon Toolbar button
When recognizing a part, the part recognition center can be designated by
dragging the crosshair with the mouse.
At this time, the center of the camera becomes the part recognition center by
default. Match the recognition center (origin point) of the polygon part to be
recognized with the crosshair center. Then the crosshair center becomes the
center of the area in which the polygon part is to be searched.
<Direction Mark> button
Sets the part placement direction.

7-66
Advanced Chip Shooter DECAN S2 Administrator’s Guide
<Direction Mark Parameter> group
<Type> combo box
None: There is no Direction Mark.
Triangle: Selected when the direction mark is a triangle.
Rectangle: Selected when the direction mark is a rectangle.
Circle: Selected when the direction mark is a circle.
H MARK: Selected when the direction mark is “H” mark.
<Threshold> edit box
The image viewed through the SM Vision window is composed of each
pixel.Each pixel has a unique value between 0 and 255 according to the
seen degree of brightness. Here, ‘Threshold Value’ indicates the border
value deciding whether each pixel should be recognized in white or black.
That is, setup the limitation for deciding if the image pixel should be black

7-67
Part Registration
or white when checking a bad mark.
The value can be adjusted by entering a numerical value in the edit box.
Check the <Auto> check box to automatically set up the <Threshold>
value.
<Size X> edit box
Displays the area size in the X direction.
<Size Y> edit box
Displays the area size in the Y direction.
<Pos X> edit box
Displays the X coordinate of the area center..
<Pos Y> edit box
Displays the Y coordinate of the area center.
<Rotation> combo box
Selects the rotating angle of the direction mark. The rotation angle can be
selected according to the direction mark type as follows:
Triangle:
Circle: The angle cannot be selected.
H Mark:
<Polarity> combo box
Select the color of fiducial mark. Available colors are as follows.
- White: the mark looks lighter than the surroundings.
- Black: the mark looks darker than the surroundings.
<Outline> button
Shows the image seen through the Vision in real display to which threshold is
not applied, or in the image (Binary) to which threshold is applied as
recognized by MMI.
<OK> button
Saves the align data and closes the dialog box.
<Cancel> button
Closes the dialog box without saving the align data.
<Move> button
Used for parts recognition test by manually picking up parts. Please refer to “Common
Align Data” for more information.