8-13 Feeder Setup  <Display> butt on Displays the sh ape of the feeder that is installed on the feeder base grap hi cally .  <Cancel> button Close the dialog box .

100%1 / 609
8-12
Advanced Chip Shooter DECAN S2 Administrator’s Guide
head and click this button.
<Installed Feeder Only> check box
Shows only the list of the feeders installed in the grid cell group for feeders.
<Part Outline> check box
If this check box is selected, when the fiducial camera is moved to the position of the
corresponding feeder to check the pickup position, the outline image that considers the
angle at which the corresponding part is picked up is displayed on the SMVision
window.
<Offset Part> button
Selected when applying the pickup offset to the same tape feeder collectively after
changing the pickup coordinate of the installed tape feeder.
<Part Offset> button
Clicking this button will automatically reflect the pickup offset of the corresponding
part on the pickup coordinate when there are parts with pickup offset among the parts
supplied by the currently installed tape feeders.
<Enable Home Offset> button
When this check box is selected, the MMI reads the Y offset value from the IT Feeder
System and corrects the Y coordination of the pickup point. Therefore, this function
can be used only when the IT Feeder System and Device Net board are installed in the
machine.
8-13
Feeder Setup
<Display> button
Displays the shape of the feeder that is installed on the feeder base graphically.
<Cancel> button
Close the dialog box.
8-14
Advanced Chip Shooter DECAN S2 Administrator’s Guide
8.1.2. Stick Unit
Install stick feeder and set data on the stick feeder. When “Stick Unit” is selected, the
initial screen looks as follows.
Figure8.5 “Stick Unit” dialog box
1: Grid group
<Grid> group
Create and edit data according to the stick unit type selected in the <Type> combo
box.
<No> column
A serial number of the stick unit slots. The number of slots of the stick feeder is as
follows. Serial number is created depending upon the number of slots.
Multi Stick - Max. 10 sets
Feeds up to 10 parts at a time.
<Part> column
Select the part to install in the corresponding slot. When the <Part> column is
clicked on, a combo box is displayed, and of the components registered in <1.2
Part>, a list of parts to be supplied to “Stick” are displayed. Select the component
to install in this list. Next is a screen showing component selection in the combo