14-54 Advanced Chip Shooter DECAN S2 Ad ministra tor’s Guid e 6. Rotate the s pi ndle i n the R-direction b y u sin g t he t eaching box s o that the shape of the nozzle holder bec om es ‘( )’. At this time, the noz z le…

100%1 / 609
14-53
Machine Calibration
3. Then the message “Please Check and Register Nozzle CNT0 to ANC 1-2 Hole. First,
We must Put all Nozzles from Heads manually. To Moving Down Z Axis, Click
[Next]” appears in the message window.Remove all nozzles inserted in the nozzle-
holder manually by clicking the <Next> button. At this time, for the ANC, the virtual
nozzle CNT0 is set for the No. 1 hole of the ANC and it is regarded that the
corresponding head picked the CNT0 nozzle.
4. Then the message “Up to Align Height and Mirror Close. To Move, Click [Next].”
appears. Then move the spindle to the part recognition height so that the nozzle holder
of the head can be seen from the fly camera and click the <Next> button to close the
mirror.
5. Execute the ‘Current Position’ dialog box by clicking the shortcut menu.
14-54
Advanced Chip Shooter DECAN S2 Administrator’s Guide
6. Rotate the spindle in the R-direction by using the teaching box so that the shape of the
nozzle holder becomes ‘( )’. At this time, the nozzle holders of the heads with
interlocked mechanism must be assembled in the same direction.
That is, the mechanisms of the #1~#2 heads and #3~#4 heads, #5~#6 heads, #7~#8
heads, #9~#10 heads must be assembled first in the same direction by using the jig for
a nozzle holder.
7. At this time, input the current position value of the R-axis and click the <Update>
button.
14-55
Machine Calibration
8. Perform the calibration form Head 2 to Head 10 in the same manner.
9. Click the <Update> button to apply the calibration result to the machine.
14.3.10.3. Light [F8]
Calibrate the brightness of the illumination for the fly camera and fix camera. For more
information please refer to “14.4. Light Mapping”.
Caution Since the nozzle for the SM32x model is not compatible to
the one for the light mapping used for the SM32x model, do